Tap ac switching characteristics, Tap timing and test condition – Cypress CY7C1143V18 User Manual

Page 17

Advertising
background image

CY7C1141V18, CY7C1156V18
CY7C1143V18, CY7C1145V18

Document Number: 001-06583 Rev. *D

Page 17 of 28

TAP AC Switching Characteristics

The Tap AC Switching Characteristics over the operating range follows.

[15, 16]

Parameter

Description

Min

Max

Unit

t

TCYC

TCK Clock Cycle Time

50

ns

t

TF

TCK Clock Frequency

20

MHz

t

TH

TCK Clock HIGH

20

ns

t

TL

TCK Clock LOW

20

ns

Setup Times

t

TMSS

TMS Setup to TCK Clock Rise

5

ns

t

TDIS

TDI Setup to TCK Clock Rise

5

ns

t

CS

Capture Setup to TCK Rise

5

ns

Hold Times

t

TMSH

TMS Hold after TCK Clock Rise

5

ns

t

TDIH

TDI Hold after Clock Rise

5

ns

t

CH

Capture Hold after Clock Rise

5

ns

Output Times

t

TDOV

TCK Clock LOW to TDO Valid

10

ns

t

TDOX

TCK Clock LOW to TDO Invalid

0

ns

TAP Timing and Test Condition

The Tap Timing and Test Conditions for the CY7C1141V18, CY7C1156V18, CY7C1143V18, and CY7C1145V18 follows.

[16]

Figure 4. Tap Timing and Test Condition

t

TL

t

TH

(a)

TDO

C

L

= 20 pF

Z

0

= 50

Ω

GND

0.9V

50

Ω

1.8V

0V

ALL INPUT PULSES

0.9V

Test Clock

Test Mode Select

TCK

TMS

Test Data In
TDI

Test Data Out

t

TCYC

t

TMSH

t

TMSS

t

TDIS

t

TDIH

t

TDOV

t

TDOX

TDO

Notes

15. t

CS

and t

CH

refer to the setup and hold time requirements of latching data from the boundary scan register.

16. Test conditions are specified using the load in TAP AC test conditions. t

R

/t

F

= 1 ns.

[+] Feedback

[+] Feedback

Advertising
This manual is related to the following products: