Power Management System

This monitor conforms to the VESA DPMS standard.
This function can reduce power consumption by the display unit.
The computer and video board being used must also conform to the VESA DPMS
standard.
* Consult the Operation Manuals for the hardware being used.

Modes change in response to input signals as indicated in the table below.

АРМ State

Screen status

Power

Indicator

color

Power

Input signals

consumption

пешгп lime

Video

Horizontal sync.

Vertical sync.

ON STATE

with display

green

normal

ON

ON

ON

STAND-BY

without display

yellow

< 1 Swatts

< 4sec.

OFF

OFF

ON

SUSPEND

without display

yellow

< 1 Swatts

< 4sec.

OFF

ON

OFF

OFF STATE

without display

yellow

< Swatts

< Ssec.

OFF

OFF

OFF

* No USB peripherals

АРМ : Advanced Power Management

Procedure:
How to release the system from the power management function

1) Read the Operation Manuals for the hardware you are using.

2) Press one of the MENU-Э В— + keys on the front panel.

The NO SIGNAL screen appears, and the monitor side power management function is

released (only in OFF STATE).

Memories

This display has two types of memory to store the data sets that control the on-screen

image. The first type of memory is the Preset Memory which is set by the factory. The

second type is the User Memory which is set by the user. Both memories store the

Horizontal Size, Vertical Size, Horizontal Position, Vertical Position, V. finetune,
H. finetune. Picture and Video signal level adjustments of the displayed image.

Preset Memory

There are 15 reservation timing that are set by the factory. The preset timing will automatically size and center
the image with video boards which use these timing. Please see page 17 tor Timing Specifications.

User Memory

• There are 16 memory locations that allow for user timing. The image size and position are adjusted by the

user. Please see page 17 for recommended timing that the display supports.

• If the User Memory is completely full, and a new set of data is saved, the oldest data set in the User Memory

will be deleted.

• When the user timing is input, the Total line, Horizontal frequencies and sync polarities of the signal are

compared with the previous data stored in memory. The input signal will be stored as a new data set if one of

its parameters is different from the previous stored one.

• The new input signal must have a frequency difference greater than that shown in the table below or a

different sync, polarity from that already stored. If the new timing data includes frequency changes greater
than those shown in the table below or sync, polarity changes, a new user memory setting will be stored. If
the frequency difference is smaller than that of the chart and the sync, polarities are the same, the existing

settings will be retained.

Horizontal frequency

Total line

Low 30 kHz ± 0.2 kHz

to

Hi 61 kHz ± 0.4 kHz

± 4 Line

Please note if the timing does not meet the display specifications, the size and position adjustment may not

appear as desired. Be sure the horizontal and vertical timing are within the monitor specification range.

See page 17 for Timing Specifications. See pages 17 and 18 for preset, reservation and recommended timing.