• How to assemble the cable

1.

strip back the cable jacket no more than 0,1 inches (3

mm) and separate the individual conductors.

2.

Prepare the individual conductors for soldering or

clamping. If clamping, use MOREX tool part

number 57027-5000 {for UL-style cable UL1015) or
57026-5000 (for UL-Style cable UL1007)

Approx.
0.1 inch

Wire

Contact

^ insert

Insert the wire until A position
and clamp the contacts.

3.

After soldering or clamping the contacts, push them

into the proper holes in the connector housing until
they snap in place.

Up

t

Wire

Contact

Caution:

Clamping the contact is a one-time procedure.

CONNECT TO 24VAC CLASS 2 SUPPLY ONLY.

Caution:

To prevent fire or shock hazard,
the UL listed wire VW-1, style 1007
should be used for the cable for AC
24V Input Terminal.

INSTALLATION OF ZOOM LENS (WV-LZ81/6)

1.

Connect the cable from the lens to female Harschman connector on the rear panel.

2.

When a zoom lens of other brand is used, change the connector with the provided Harschman connector.
Refer to the pin configuratioa

Rn configuration

1 DC COM

2 IRIS
3 FOCUS
4 ZOOM

CAUTION:

• Clamp the cables not to contact with the heater unit or other electrical components.

TYPICAL SYSTEM CONNECTIONS

System Controller

WV-CU254

^

^ .A.

II _

B B o

Coax. Cable

Monitor

AC 120V

60Hz

U,

AC 120V 60Hz