Maximum ratings, Pin configuration, Operating range – Cypress CY7C1399B User Manual

Page 2: Electrical characteristics

Advertising
background image

CY7C1399B

Document #: 38-05071 Rev. *A

Page 2 of 10

Maximum Ratings

(Above which the useful life may be impaired. For user guide-
lines, not tested.)

Storage Temperature ................................. –65

°

C to +150

°

C

Ambient Temperature with
Power Applied............................................. –55

°

C to +125

°

C

Supply Voltage on V

CC

to Relative GND

[1]

.... –0.5V to +4.6V

DC Voltage Applied to Outputs
in High Z State

[1]

....................................–0.5V to V

CC

+ 0.5V

DC Input Voltage

[1]

................................–0.5V to V

CC

+ 0.5V

Output Current into Outputs (LOW)............................. 20 mA

Static Discharge Voltage .......................................... >2001V
(per MIL-STD-883, Method 3015)

Latch-Up Current .................................................... >200 mA

Pin Configuration

22

23

24

25
26

27

28
1

2

5

10

11

15

14
13

12

16

19

18

17

Top View

TSOP

3

4

20

21

7

6

8

9

OE

A

1

A

2

A

3

A

4

WE

V

CC

A

5

A

6

A

7

A

8

A

9

A

0

CE
I/O

7

I/O

6

I/O

5

GND
I/O

2

I/O

1

I/O

4

I/O

0

A

14

A

10

A

11

A

13

A

12

I/O

3

Operating Range

Range

Ambient

Temperature

V

CC

Commercial

0

°

C to +70

°

C

3.3V

±

300 mV

Industrial

–40

°

C to +85

°

C

3.3V

±

300 mV

Electrical Characteristics

Over the Operating Range

[1]

7C1399B-10

7C1399B-12

Parameter

Description

Test Conditions

Min.

Max.

Min.

Max.

Unit

V

OH

Output HIGH Voltage

V

CC

= Min., I

OH

= –2.0 mA

2.4

2.4

V

V

OL

Output LOW Voltage

V

CC

= Min., I

OL

= 4.0 mA

0.4

0.4

V

V

IH

Input HIGH Voltage

2.2

V

CC

+0.3V

2.2

V

CC

+0.3V

V

V

IL

Input LOW Voltage

–0.3

0.8

–0.3

0.8

V

I

IX

Input Load Current

–1

+1

–1

+1

µ

A

I

OZ

Output Leakage
Current

GND

V

I

V

CC

,

Output Disabled

–5

+5

–5

+5

µ

A

I

OS

Output Short
Circuit Current

[2]

V

CC

= Max., V

OUT

= GND

–300

–300

mA

I

CC

V

CC

Operating

Supply Current

V

CC

= Max., I

OUT

= 0 mA,

f = f

MAX

= 1/t

RC

60

55

mA

I

SB1

Automatic CE Power-Down

Current — TTL Inputs

Max. V

CC

, CE

V

IH

,

V

IN

V

IH

, or V

IN

V

IL

,f = f

MAX

5

5

mA

L

4

4

mA

I

SB2

Automatic CE Power-Down

Current — CMOS Inputs

[3]

Max. V

CC

, CE

V

CC

– 0.3V, V

IN

V

CC

– 0.3V, or V

IN

0.3V,

WE

V

CC

– 0.3V or WE

0.3V, f = f

MAX

500

500

µ

A

L

50

50

µ

A

Notes:

1.

Minimum voltage is equal to – 2.0V for pulse durations of less than 20 ns.

2.

Not more than one output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.

3.

Device draws low standby current regardless of switching on the addresses.

Advertising