Troubleshooting
If a problem is encountered, investigate it by referring first to the table below. If you cannot correct
it, unplug the power plug and consult an authorized service dealer.
Symptom
The product does not operate.
No air comes out. Abnormally
loud operating sound.
The product continues
operating in the AUTO mode.
Odors are not removed.
Smoke is not removed.
The operating sound is
abnormally loud.
The product is not activated
by smoking. The product is
not activated in spite of high
levels of house dust.
The air quality indicator bar
stays green all the time.
н=н>
Check point
Page
Is the power plug disconnected from the outlet?
5
Is the plastic sheet removed from the main unit?
Remove the plastic sheet.
5
Is the air dusty? (excessive dust)
Is dusty outside air getting in?
4
Is the main unit or air intake grille dirty?
Clean it. If the symptoms still remain unchanged,
replace the Deodorizing filter with a new one.
8,9
Is the filter full of dust? (clogged)
Clean the HEPA filter. If the symptoms still
remain unchanged, replace the HEPA filter with
a new one.
8,9
Is the product installed where it is actually exposed
to tobacco smoke and house dust?
Install it in another place or use Continuous
operation mode.
6
Is the micro dust sensor dirty?
Clean the micro dust sensor with the cleaning
pad.
10
Is there airborne dust in the air?
This is normal when dust is settled in the room
and is not disturbed by room activity.
4
1 1