Installation technical data, Technical data, Troubleshooting – STIEBEL ELTRON MINI 6-2 User Manual

Page 9: En gl ish

Advertising
background image

EN

GL

ISH

WWW.STIEBEL-ELTRON-USA.COM

MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS |

9

INSTALLATION

TECHNICAL DATA

11. Technical

data

Model

Mini

2-1

Mini

2.5-1

Mini

3-1

Mini

3.5-1

Mini

4-2

Mini

6-2

Item number

231045

232098

220816

232099

222039

220817

Phase

1

1

1

1

1

1

Voltage

V

115 - 125

115 - 125

115 - 125

115 - 125

208

240

208

240

Wattage

kW

1.8

2.4

3.0

3.5

2.9

3.5

4.7

5.7

Max. amp, load

A

16

21

25

31

13.8

15.2

22.4

24.7

Min. required circuit
breaker size

A

20

30

30

40

20

20

30

30

Required wire size

AWG COPPER

12

10

10

10

12

12

10

10

Min. water flow to
activate unit

GPM

(

l/min)

0.21

(0.8)

0.40

(1.5)

0.40

(1.5)

0.40

(1.5)

0.40

(1.5)

0.77

(2.9)

Recommended inlet
temp. range

°F (°C)

41-77 (5-25)

Nominal water volume

GAL (l)

0.026 (0.1)

Working pressure,
max.

PSI (bar)

150 (10)

Tested to pressure

PSI (bar)

300 (20)

Weight

lbs. (kg)

3.44 (1.56)

Dimensions

Height
Depth
Width

inch (mm)
inch (mm)
inch (mm)

6

1

/

2

(165)

3

1

/

4

(82)

7

1

/

2

(190)

Water connections

for 3/8˝ O.D. flex connector

Heating System

Nichrome bare-wire

Mini

2-1 models are internally restricted to 0.32 gpm. Mini

2-1, 2.5-1, 3-1 ship with a 0.5 gpm pressure compensating fl ow reducer/aerator that should be installed.

Mini

3.5-1, 4-2 ship with a 0.66 gpm pressure compensating fl ow reducer/aerator that should be installed.

-Tankless water heaters are considered a non-continuous load
-Conductors should be sized to maintain a voltage drop of less than 3 % under load
-For use with cold water supply only

12. Troubleshooting

E

Symptom

Possible cause

Solution

No hot water
despite fully
opened hot
water faucet.

No electrical power.

Check the circuit breaker and
check voltage at the wiring block.

The activation fl ow rate needed to
turn on the heating element has not
been reached.

Clean fi lter screen.

Safety cut out tripped

– turn circuit breakers off
– open Hot Valve to release pres-

sure from the unit

– reset saftey pressure cut out

E

– turn circuit breakers on

Advertising