Installation, Installation mounting the appliance, Mounting the appliance – STIEBEL ELTRON DHC-E 12 User Manual

Page 5: 1 application, 2 mounting, 3 water connections

Advertising
background image

EN

GL

ISH

WWW.STIEBEL-ELTRON-USA.COM

DHC-E |

5

INSTALLATION

MOUNTING THE APPLIANCE

INSTALLATION

5. Mounting the appliance

5.1 Application

One appliance can be used for the following applications:

one or multiple hand washing sinks

one kitchen sink

cabins with fl ow restriction at shower head.

A combination of two appliance can be used for whole apartment
and house applications. Please contact STIEBEL ELTRON for special
installation instructions.

All areas with a ground water temperature likely to exceed 65 °F
(18 °C) year round:

Whole apartment or house

CAUTION Electrocution
Unit must be installed in a vertical position with the
water fi ttings pointing downward. In this position the
unit is splashproof, so that no water can soak in.

1

2
3

4

5
6

7

26

_0

2

_02

_1

0

82

1

2
3

4

5
6

7

26

_0

2

_02

_1

0

81

1 Hot valve (left)
2 Cold valve (right)
3 Sink
4 1/2“ main pipe
5 Water supply line for faucet installation
6 Shut-off valve
7 Electrical junction box

5.2 Mounting

 Install appliance as close as possible to the main hot water

draw-off points.

 Install appliance in a frost free area. If frost may occur, re-

move appliance before freezing temperatures set in.

 Leave a minimum of 5“ of clearance on all sides for servicing.

26

_0

2

_02

_1

0

83

 Remove plastic cover.

26

_0

2_0

2

_0

33

1

26

_0

2

_02

_1

0

9

0

 Screw the screws into the wall and hang the appliance.

Screws and plastic wall anchors for mounting on masonry or
wood are provided.

 Secure the screws.

5.3 Water

connections

!

Damage to the appliance and the environment
Excessive heat from soldering on copper pipes near the
DHC may cause damage.