STIEBEL ELTRON SOL 25 PLUS User Manual
Page 16

16
| SOL 25 PLUS
WWW.STIEBEL-ELTRON-USA.COM
Roof Pitch (rise-to-run)
Roof Pitch Angle
Resulting Collector Tilt Angle with 45° Mount
1-in-12
4.8°
49.8°
2-in-12
9.5°
54.5°
3-in-12
14.0°
59.0°
4-in-12
18.4°
63.4°
5-in-12
22.6°
67.6°
6-in-12
26.6°
71.6°
7-in-12
30.3°
75.3°
8-in-12
33.7°
78.7°
9-in-12
36.9°
not recommended
10-in-12
39.8°
not recommended
11-in-12
42.5°
not recommended
12-in-12
45.0°
not recommended
Table 5.2.9: Resulting Inclination Angle When Mounting a 45° Kit to Various Roof Pitches
At least 25 ft. (7.6 m)
Array spacing for 45° Vertical Mounting
on a flat roof or ground.
Figure 5.2.10: Recommended row spacing for 45° vertical arrays for latitudes up to 50°.
At least 14 ft. (4.0 m)
Array spacing for 45° Horizontal Mounting
on a flat roof or ground.
Figure 5.2.11: Recommended row spacing for 45° horizontal arrays for latitudes up to 50°.