Revision 2.0

4.7 F

USING

Y

OUR

S

YSTEM

It is necessary to add fuses or circuit breakers to the Complete Off-Grid Solar Panel Kits. While the systems will
function without fuses or circuit breakers, fusing protects the system from accidental short circuits, power
surges, and accidental incorrect wiring. An ATC fuse can be used (available at auto parts stores) or a circuit
breaker can be purchased at most hardware stores. The table below shows the recommended fuse/breaker size
for each system based on 12 or 24 volt configurations.

Solar Kit Size

12 Volt System

Breaker Size

24 Volt System

Breaker Size

100W

10 Amps

N/A

200W

20 Amps

10 Amps

300W

30 Amps

N/A

400W

40 Amps

20 Amps


The figure below shows where the fuses or circuit breakers should be placed.

Wiring diagram example of two 100 Watt solar panels wired for 24 volt battery charging showing the

fuse/breaker locations.

4.8 G

ROUNDING

Although not required for low voltage, the panel can be grounded by connecting a conductive wire the frame.