grommet  as  shown  in  Step  1  of  Figure  3.  This  is  because  some  strains  reliefs  use  a  non-­‐
removable  grommet.  If  there  is  no  grommet,  you  only  need  to  remove  the  nut  from  the  strain  
relief.  
Step  2:  It  is  highly  recommended  that  Step  2  be  performed  using  two  people.  Person  #1  guides  
the  three  wires  out  the  top  of  the  strain  relief  while,  at  the  same  time,  Person  #2  slides  the  yaw  
mount  onto  the  tower  pipe.  
 
 
 
Wiring  the  Generator  to  the  Slip  Ring:  
 

Figure  4:  Generator  wiring  diagram  

 

 

 
Step  1a:  
If  your  strain  relief  has  a  free  grommet,  insert  the  plastic  grommet  back  into  the  strain  
relief.  If  you  there  is  no  free  grommet,  proceed  to  Step  1b.  
Step  1b:  Gently  pull  on  all  three  wires  coming  out  of  the  strain  relief  until  you  feel  tension  in  all  
three  wires.  While  continuing  to  hold  tension  on  all  three  wires,  use  your  fingers  to  tighten  the  
strain  relief  nut.  Tighten  the  strain  relief  nut  very  firmly  with  your  fingers  until  it  is  “finger  tight”  
as  shown  in  step  1  of  Figure  4.  You  may  use  a  wrench  to  gently  tighten  the  strain  relief  nut  but  
firmly  tightening  it  with  your  fingers  is  sufficient.  If  you  choose  to  use  a  wrench,  take  great  care  
not  to  over  tighten  the  strain  relief  nut.  The  strain  relief  accomplishes  two  tasks:  (1)It  removes  
any  wire  slack  from  inside  the  yaw  mount  which  could  cause  the  wires  to  rub  against  the  metal  
pipe  walls  inside  the  yaw  mount.  (2)  The  strain  relief  forms  a  water  tight  seal  which  keeps  water  
out  of  the  inside  of  the  yaw  mount  and  slip  ring.  