Step 1.

Begin removal of the OEM system by

unclamping the OEM Extension Pipe and muffler
from the junction behind the DPF. You can then
disengage the welded hangers from the rubber
insulators, working rearward finish removing the
system. Do not damage or discard the rubber
insulators or sensor bracket and fastener, as they
will be reused to mount the new system

.

Step 3.

Next Install the Tail Pipe Assembly in a

similar fashion using the supplied 4.00" clamps and
by fitting the welded hangers into the rubber
insulators.

Step 2.

Begin installation of the Magnaflow system

by clamping the Inlet Pipe to the outlet of the DPF
using a supplied 4.00" clamp and fitting the hangers
in the rubber insulators (leave all clamps loose for
final adjustment of the complete system).

Step 4.

Once a final position has been chosen for

the new exhaust system, evenly tighten all clamps
from front to rear using the torque specifications on
page one of the instructions. Inspect all fasteners
after 25-50 miles of operation and re-tighten if
necessary.

Advertising