User’s manual aw900r2-eval – AvaLAN Wireless AW900R2-EVAL User Manual

Page 7

Advertising
background image

PAGE 7

Technical support (650) 384-0000

www.avalanwireless.com

User’s Manual

AW900R2-EVAL

5. Use the dropdown menu labeled “Boot Config Serial Port” to select the virtual

COM port connected to your AW900R2 module. Note that the list is populated only

when EvkUtilityLite first starts. If you change your cable connection or plug in an-

other module, restart the utility to see the changes. Next click the “Get” button to

fetch the current configuration from the module.
6.

If you are satisfied with the module’s configuration and status, stop here. If

changes are needed, here is an explanation of the parameters that may be set on

the Boot Configuration page:

Radio Configuration

Meaning

AccessPoint/Subscriber

Unit

Radio buttons to select whether this module is the master or the client of

the pair. Each RS-232 wireless link must have an Access Point at one end and

a Subscriber Unit at the other.

Number of Subscriber

Units/Subscriber ID

A two digit number, leading zero required, that must be set to “01” for

these AW900R2 modules. (Other numbers are needed for multi-drop RS-485

versions.)

Channel 00-12

The RF channel for the module. The frequencies corresponding to each chan-

nel are shown in the table on page 5. Choose “00” for automatic channel

selection or set “01” to “12” for a fixed choice.

Network Name

A 32-bit value (8 Hex digits, 0 to 9 and A to F) that must be the same for the

two radio modules of the link. If you have multiple links operating in the

same vicinity, give each link a unique value.

AES Private Key

A 128-bit value (32 Hex digits) that must be the same for the two radio mod-

ules in the link. This key is used to encrypt the transmitted data and decrypt

the received data.

4. Run EvkUtilityLite.exe and you should see a window like this:

Advertising