Get new sample alignment lock value – Aviom 6416dio User Manual
Page 69

59
A
dvANced
F
uNctioNs
The Input section Slot display is used to provide sample alignment
information.
To get sample alignment info, press the
F
unCtion
button, followed by the
ChannEl
11 a
CtivE
button. Press
E
ntEr
. The Sample Calibration status will be
indicated in the Input section’s A‑Net Slot display.
If Sample Calibration is enabled, the display will blink a “1”
•
in the Slot display for three seconds.
If Sample Calibration is disabled, the display will blink a “0”
•
in the Slot display for three seconds.
Get New Sample Alignment Lock Value
To generate a new sample alignment lock value, use Function 12. This
function can only be performed at the Control Master when the network is
unlocked.
Press the
F
unCtion
button, followed by
ChannEl
12 a
CtivE
button. The sixteen
yellow channel meter LEDs and the Enter/Cancel LED will flash, indicating that
this operation will replace the currently stored value. Press
E
ntEr
to generate
a new sample alignment value, or press
C
anCEl
to exit without updating the
stored value.
Values are stored in each module’s memory but are not put into use until
Function 13 (Use Stored Sample Alignment Values) is performed, which
activates the stored sample alignment values. The module must be the
network Control Master to use its stored value. Use Function 11 to get info on
the current values in use.
When the stored sample alignment lock value is being used, a new sample
alignment lock value should be calculated each time the network sample rate
is changed, or when the system configuration changes. (Changes include the