Checkline DT-326 User Manual

Page 31

Advertising
background image

28

4.7 Connector of External input/output

4.7.1 Connector specs and pin type

Pin No

Single name

Remarks

1

+12V

+12V power supply output

2

G12

Ground power supply output

3

TRG_IN

External pulse input

4

IN_COM

Universal interface of External pulse input

5

NC

(no connection)

6

NC

(no connection)

7

OUT

External pulse output

8

OUT_COM

Universal interface of External pulse output

9

NC

(no connection)

10

FG

Ground electrode of frame work

Connector type DT-326 side: 3260-10S3 (55) [HIROSE ELECTRIC CO., LTD.]

Accessory: 3240-10P-C [HIROSE ELECTRIC CO., LTD.]

4.7.2 External Pulse Input

The unit can be operated and controlled by an external signal, from either a sensor or a machine signal like

an output from a printing press, re-winder or others. This will allow the stroboscope to flash in sync with the

target object’s rotational speed.

The input signal will have the following characteristics.

Input frequency: 60 - 10,000 FPM (1 – 160 Hz)

Input pulse width: over 50us

Delay angle: 0 - 359°

(

every 1°)

Delay time: 0 - 999ms (every 1ms)

Please connect with open collector output (below 1V (ON voltage)) or no-voltage contact output

(approx. 11mA current)

4.7.3 External pulse output

The unit will also output a signal that is related to the flash rate of the unit. This signal can be used to control

additional stroboscopes so that each flashes at the same rate or to send a pulse to data collectors.

External circuit: Open collector output, Voltage below DC30V, Current below 30mA

Output pulse width: Approx. 200us

Connector of
External
input/output

3pin

4pin

+12V

Inside DT-326

Photocoupler

1k

7pin

8pin

Inside DT-326

Photocoupler
(Same as TLP127 Toshiba)

(36V)

[Output circuit]

[Output time]

[Input circuit]

Flashing

External
pulse output

Approx. 200us

Advertising