Power-on programming – Checkline HTG2 User Manual

Page 5

Advertising
background image

page 12

page 5

Programming Setpoints (optional)
Program High and Low setpoints for easy GO/NO GO testing.

1. Turn on the gauge

2. Press

and

for 3 seconds to enter Power-On program-

ming mode (CF9 flashes with solid F0).

3. Press

to display flashing CF9 with solid F1,

then press

to display –HI– and then the

high set value (i.e. H 10.0).

4. Press

to increase and

to decrease the

High set value, then press

to display –LO–

and then low set value (i.e. L 5.0). Press

to

increase and

to decrease the Low set value and press

to display flashing CF9 with solid End.

5. Press

again to exit Power-On programming mode.

HIGH SETPOINT

LOW SETPOINT

Reversing the Display
The factory default is standard display.
To reverse the display:

1. Turn on the gauge

2. Press

and

for 3 seconds to enter

Power-On programming mode (CF9 flashes

with solid F0).

3. Press

5 times to display flashing CF9 with solid F5, then

press

to display -12345. Press

or

, to cycle between

standard and reverse

.

4. Press

to select, the display flashes CF9 with solid End.

5 Press

again to exit Power-On programming mode.

Once desired display is selected, the gauge retains it as a default.

-1

23

45

DIGITAL FORCE GAUGE

00.0

NG

Lb-in

OK

+NG

OVERLOAD

ZERO

SEND

PEAK

ON

OFF

DIGIT AL FORCE GA

UGE

00.0

NG

Lb-in

OK

+NG

OVERLO

AD

ZERO

SEND

PEAK

ON

OFF

STANDARD

DISPLAY

REVERSE

DISPLAY

Power-On programming

Turn on the gauge. Press

and

for 3 seconds to enter

Power-On programming (CF9 flashes with solid F0). Press

or

to cycle CF9 F0, CF9 F1, CF9 F2, CF9 F3, CF9 F4, CF9 F5,

CF9 F6 and CF9 End. Press

to select a function.

CF9 F0

Memory recall

Press SEND, memory location and value cycle. Press PEAK or ZERO to increase or
decrease memory number (and corresponding value). Press SEND to exit.

CF9 F1

High & low setpoints

Default=‘0’ both Hi and Lo

Press SEND, –HI– displays, then the high set value (i.e. H 10.0). Press PEAK to
increase and ZERO to decrease, press SEND to select. –LO– displays then the low set
value (i.e. L 5.0). Press PEAK to increase and ZERO to decrease, press SEND to select,
CF9 End displays. Press SEND again to exit.

CF9 F2

Peak mode

Default=‘Or’

Press SEND, ‘Or’ or ‘And’ displays. Press PEAK or ZERO to cycle. Press SEND to
select. ‘Or Peak’ records the Peak in either CW or CCW during test. ‘And Peak’ records
both the CW peak and CCW peak during a test.

Zero reset memory store

Default=‘AA-OFF’

Auto memory displays after Peak mode is selected. ‘AA-On’ enables automatic memory
storage and reset to zero. ‘AA-OFF’ turns off auto function. Press PEAK or ZERO to
change. Press SEND to select, CF9End displays, press SEND again to exit.

CF9 F3

Auto zero reset

Default=‘Ac-OFF’

Press SEND, ‘Ac-On’ or ‘Ac-OFF’ displays. Press PEAK or ZERO to cycle. If ‘AC-On’ is
selected, auto zero reset duration can be programmed. Press PEAK to increase or
ZERO to decrease. Press SEND to select, CF9End displays, press SEND again to exit
(i.e. ‘SEC 3.0’ is displayed for auto zero reset duration of 3 seconds).

CF9 F4

Audible beep

Default=‘Sd-On’

Press SEND, ‘Sd-On’ for alarm on, or ‘SD-OFF’ for off displays. Press PEAK or ZERO to
cycle. Press SEND to select. CF9End displays, press SEND again to exit (alarm sounds
for values over HI or under LO setpoints).

Setpoint alarm

Default=’’

Setpoint alarm displays after audible beep is selected. ‘AL-On’ for setpoint alarm on or
‘AL-OFF’ for off. Press PEAK or ZERO to cycle. Press SEND to select, CF9End displays,
press SEND again to exit.

CF9 F5

Reverse display

Press SEND, ‘-12345’ for standard or ’

’ for reverse displays. Press PEAK or

ZERO to cycle. Press SEND to select. Flashing CF9 with solid End displays. Press
SEND again to exit. (for vertical mounting).

CF9 F6

Auto power off duration

Default=‘AO-10’

Press SEND, ‘AO-10’ displays. Press PEAK or ZERO to cycle ‘AO-5’ for 5 min auto
power off duration, ‘AO-10’ for 10 min, ‘AO-30’ for 30 min, ‘AO-60’ for 60 min and ‘AO-
OFF’ to by-pass auto power off. Press SEND to select, CF9End displays, press SEND
again to exit.

-12

34

5

Advertising