COP-USA AS75W User Manual

Page 6

Advertising
background image

3

ON

1 2 3 4 5 6 7 8 9 10

ON

1 2 3 4 5 6 7 8 9 10

ON

1 2 3 4 5 6 7 8 9 10

ON

1 2 3 4 5 6 7 8 9 10

ON

1 2 3 4 5 6 7 8 9 10

ON

1 2 3 4 5 6 7 8 9 10

P/ T Addr ess=1

P/ T Addr ess=2

P/ T Addr ess=3

P/ T Addr ess=4

P/ T Addr ess=5

P/ T Addr ess=511

2

、

Selection of the Terminal Resistor

As shown in Figure 1, DIP10 of the ID-CODE is the select switch of the 120

Ω

terminal resistor on the bus RS485, on which only one terminal resistor of the dome

camera at the farthest end can be connected, while the terminal resistors of other

devices should be opened.

3

、

Setup of the Protocol and the Default Baud Rate

As shown in Figure 1, SW2 is used to set the protocol of communication and the

baud rate used by the dome camera. DIP-4 to DIP-1 of SW2 is used to select protocols

and 16 different protocols can be selected in maximum. Following table shows states

of coding switches of protocols selected by the dome camera in which

●

means the

protocol has been integrated while

○

means the protocol is temporarily vacant.

Type of Protocols

Selection of Protocols

Normal Baud Rate Integrated

Protocol

DIP1 DIP2 DIP3 DIP4 DIP5 DIP6

SAMSUNG ON

OFF

OFF

OFF

OFF

ON

●

NEON ON

OFF

OFF

OFF

OFF

ON

●

Reserved OFF

ON

OFF

OFF

OFF

ON

○

PELCO-D ON

ON

OFF

OFF

OFF

OFF

●

PELCO-P/4800

OFF OFF ON OFF

ON OFF

●

PELCO-P/9600 OFF

ON

PANASONIC ON

OFF

ON

OFF

OFF

ON

○

Longcomity OFF

ON

ON

OFF

OFF

ON

●

HUNDA600 ON

ON

ON

OFF

OFF

ON

●

LILIN OFF

OFF

OFF

ON

ON

OFF

○

VICON ON

OFF

OFF

ON

ON

OFF

○

MOLYNX OFF

ON

OFF

ON

OFF

ON

○

KALATEL ON

ON

OFF

ON

ON

OFF

○

VCL OFF

OFF

ON

ON

OFF

ON

○

DAIWA ON

OFF

ON

ON

OFF

ON

●

ALEC OFF

ON

ON

ON

OFF

ON

●

Ultrak ON

ON

ON

ON

OFF

ON

●

Table 2

Some protocols and the states of the coding switches of normal baud rate of these

Advertising