2.11. The key switch has four spade terminals.

See Figure 2.11.

The red wires with white trace (terminal A & B)
are fused constant hot-leads.

In the OFF position, no terminals are connected.

In the RUN position, only terminals B and C are
connected to, sending power through the red
wire with black trace to the lighting and acces-
sory circuits and pin # 18 (run input) on the
instrument panel.

The START position makes the “RUN” con-
tacts, and A terminal and D terminal are con-
nected to each other, sending power through the
orange wire to pin #16 (start input) on the panel.

2.12. The instrument panel is easily unplugged or

removed with the hood open. See Figure 2.12.

2.13. The pin numbers are indicated on the molded

connector. See Figure 2.13.

2.14. Each number corresponds to a pin position on

the instrument panel. See Figure 2.13.

Figure 2.11

Figure 2.12

Mounting Bolts

Molded connector

Figure 2.13

“8”

“1”

back row: # 16 -> # 23
center row: # 9 -> # 15
near row: # 1 -> # 8

“16”

“23”

Figure 2.14

Pins on instrument
panel connection