81
7.
Connect the positive side of the power source to the
terminal that has the piggy back wire on it. See Fig-
ure 6.18.
8.
Reconnect the DMM with it still on the Ohms (
)
scale. See Figure 6.19.
NOTE: The DMM should read less than 0.2 Ohms (
).
This relay has a burnt contact.
9.
If the test results do not match what was listed above,
replace the relay.