Hardy Advantage Lite HI LPRE Load Points User Manual

Advantage lite series: hi lpre

Advertising
background image

ADVANTAGE LITE SERIES: HI LPRE

INSTALLATION AND ASSEMBLY INSTRUCTIONS

Model Numbers

CAPACITY

Load Point
Model Number

Load Sensor
Model Number

LB

KG

440

200

HI LPRE440-33C

HI SB02-440

1100

500

HI LPRE1.1K-33C

HI SB02-1.1K

2200

1000

HI LPRE2.2K-33C

HI SB02-2.2K

4400

2000

HI LPRE4.4K-33C

HI SB02-4.4K

Basic Engineering Principle for Positioning Load Point
Assemblies

Load Point Assemblies should be positioned such that the

load (weight) is distributed as evenly as possible between

each load point assembly in the scale.

Site Preparation

All foundations for the HI LPRE load point assemblies

require a metal base plate adequate to prevent any deforma-

tion of the plate when welding the base or spacer of the load

point assembly to the foundation.

All mounting surfaces for the base and loading plate must be

level. The Load Point Assemblies in a system must be level
to within ± 0.5

o

.

Welding should be done prior to the installation of the load

sensor. Otherwise disconnect load sensor wiring from the

instrument and bypass each load sensor with heavy ground

strap from live weight side of each load point to earth

ground.

Precautions

Always treat the Load Sensor as a precision instrument.

Leave the assembly in its packaging until it is time for instal-

lation.

NEVER CARRY OR SWING THE LOAD SENSORS
BY THEIR CABLE.

Never allow moisture to get into any interconnections.

Keep the Load Point Assembly free of debris.

Physical Dimensions

MODEL #

A

B

C

HI LPRE440-33C

6.13 (155.8)

3.15 (80.0)

3.27 (83.0)

HI LPRE1.1K-33C

6.13 (155.8)

3.15 (80.0)

3.27 (83.0)

HI LPRE2.2K-33C

6.13 (155.8)

3.15 (80.0)

3.27 (83.0)

HI LPRE4.4K-33C

6.13 (155.8)

3.15 (80.0)

3.27 (83.0)

MODEL #

D

E

F

HI LPRE440-33C

4.22 (107.1)

2.28 (58.0)

2.52 (64.0)

HI LPRE1.1K-33C

4.22 (107.1)

2.28 (58.0)

2.52 (64.0)

HI LPRE2.2K-33C

4.22 (107.1)

2.28 (58.0)

2.52 (64.0)

HI LPRE4.4K-33C

4.22 (107.1)

2.28 (58.0)

2.52 (64.0)

MODEL #

G

H

Height*

HI LPRE440-33C

2.12 (53.9)

1.44 (36.5)

3.37 (54.7)

HI LPRE1.1K-33C

2.12 (53.9)

1.44 (36.5)

3.37 (54.7)

HI LPRE2.2K-33C

2.12 (53.9)

1.44 (36.5)

3.63 (92.1)

HI LPRE4.4K-33C

2.12 (53.9)

1.44 (36.5)

4.59 (116.6)

*

Measured from the bottom of the base to the top plate bolts.

Electrical Termination Cable Color Codes

WARNING: Load cell cable length has been calculated
into C2 calibration data. Hardy Process Solutions rec-
ommends that you do not cut your Advantage or
Advantage Lite load sensor cable, as your C2 accuracy
will be affected and the warranty will be voided.

Advertising