5 CONFIGURE SCALE
-------------------------------------------------------------------
The IDS550 prompts: "CONDEC/WS700T" (or current meter
that is selected.)
The meter select menu is:

"NCI5790"
"ANALOGIC AN5316"
"CONDEC / WS700T"
"AND / GENERAL"
"CARDINAL 738"
"TOLEDO 8142"
"WI 110"
"DR 10K"
"SSD800"
"HR 50 LIBERATOR"
"FB90-165"

Press the CONTINUE key to scan the meter list. Press the ENTER
key to select a meter type.

The IDS550 prompts: "UNITS = XXXX"
where XXXX = the scale units being sent by the scale indicator.
Note: if the scale input units do not match the units configured
the IDS550 display will show the error message: -U-

The scale units menu selections are:

"UNITS = UNDEF." - units not set.
"UNITS = LB" - sets units to lbs.
"UNITS = KG" - sets units to kgs.
"UNITS = TON" - sets units to tons.
"UNITS = TNE" - sets units to metric tons.

Press the CONTINUE key to scan the scale units selections . Press
the ENTER key to complete the scale units selection.

The IDS550 prompts: "COUNT BY XX"
where XX = count-by graduations of the weight indicator. Press
the ENTER key to use the displayed count-by or enter a new
count-by number. The valid count-by's are:
.01 .02 .05 0.1 0.2 0.5 1 2 5 10 20 50