Industrial Data Systems IDS 550 User Manual

Page 9

Advertising
background image

If the IDS550 internal motion detect option is installed -

The IDS550 prompts: "MOTION TIME XX"
where XX is the time between motion detect samples (tenths of
seconds). Press ENTER to use the displayed time or enter a new
motion detect interval time.

The IDS550 prompts: "MOTION RANGE XX"
where XX is allowable weight deviation for the scale = not in
motion. Press ENTER to use the displayed range or enter a new
motion detect range.

If the IDS550 setup matches the meter setup and the scale
weight is NOT displayed on the IDS550 then see the section:
"IDS550 Troubleshooting Guide".

NOTE: The IDS550 circuit board has a slide switch that
selects between RS232 and Current Loop input. Push
the slide to the left (towards the print mechanism)
for RS232. Push the slide to the right (away from
the print mechanism) for Current Loop.
6 CONFIGURE PRINTER
-------------------------------------------------------------------
The IDS550 prompts: "INHIBIT ON PE x" for inhibit print if
Paper Empty. The x is 'Y' for yes or 'N' for no. Enter a 1 for
'Y' or 0 for 'N'. Press the ENTER key to complete the entry.

The IDS550 prompts: "INVERT PRINT x" where x is 'Y' for yes
or 'N' for no. Enter a 1 for 'Y' or 0 for 'N'. Press the ENTER
key to complete the entry.

The IDS550 prompts: "MULTI-STRIKE x" where x is a number
between 0 and 9. This function is used to make multi-part forms
more legible by printing each line multiple times. Enter a 0
to disable multi-strike or enter the number of extra times to
print each line. If multi-strike is enabled, bi-directional
printing is disabled.


7 CONFIGURE PASSWORD
-------------------------------------------------------------------
There are 2 password levels. Password level 1 protects access
to the erase ID functions and the clear memory functions.
Password 2 protects access to the configure functions.

LEVEL 1 PROTECTED FUNCTIONS: (Application dependant)

LEVEL 2 PROTECTED FUNCTIONS: CONFIGURE

Activate the CONFIGURE menu and press the ENTER key when the
IDS550 displays 'CONFIG PASSWORD'.

The IDS550 prompts: "EN PASSWORD 1 N"
Enter a 'Y' (1) to enable the password or an 'N' (0) to disable
the password. If 'Y' (1) is entered the IDS550 prompts:
"ENTER PASSWORD 1". Enter up to 7 digits for the new password.
Press the ENTER key to complete the password entry.