3 Select the Frequency Band

EchoStream products use a range of radio frequencies, and must be
configured for your geographic area. To configure the receiver:
1. Use a small screwdriver to press the housing release tabs on the top or

bottom of the receiver; separate the housing.

2. Place a selection jumper on the appropriate frequency band selection

pins.

• Leave the jumper off the pins to set the frequency range to 902-928

MHz for North America.

• Place the jumper on the top two pins, marked NZ, to set the frequency

range to 921-928 MHz for New Zealand

• Place the jumper on the bottom two pins, marked AUS, to set the

frequency range to 915-928 MHz for Australia.

Note: North American is also selected when the jumper is only attached to
one pin. This can prevent the jumper from being lost when selecting North
America.

Note: Only devices set for use in North America are configured for UL
installations.

3. Cycle power to reset.

4 Connect Input/Output Cabling

1. Connect cabling to the receiver power loss output. Must be configured

for UL installations.

• The receiver power loss output is a normally closed (N/C) output that

opens when the receiver loses power.

2. Connect cabling to the tamper output. Must be configured for UL

installations.

• The tamper output is a normally open (N/O) output that reports

receiver case tamper to an external device.

3. Connect cabling to the jam output. Must be configured for UL

installations.

• The jam output is a normally closed (N/C) output that opens when

noise thresholds on all receive channels remain above a
predetermined value for 10 seconds. The jam output is set to the
follower output type.

4. Connect a momentary switch to the reset input and ground. Must be

configured for UL installations.

• The reset input circuit permits installation of a remote momentary

normally open (N/O) switch to clear faults, unlatch outputs, and reset
the receiver to a normal state.

5. Connect cabling to the output terminals. Must be configured for UL

installations.

• The EN4216MR provides six Form-C relays.

6. Close receiver housing.

Figure 4 EN4216MR Terminals

5 Mount the Receiver

Caution: Mount the receiver in a location removed from metal. Metal
objects (duct work, wire mesh screens, boxes) will reduce RF range.

Note: For UL listed systems containing a UL hold-up switch, the
EN4216MR must be located within three feet of a system keypad in a
location out of sight from the protected premise.

Note: For UL installations, the EN4216MR must be in the same room as
the control panel.

1. Use the provided anchors and screws to mount the receiver in a

location accessible for future maintenance.

2. Perform a walk test, activating each transmitter assigned to the receiver

and ensuring a good signal.

6 Factory Configuration Defaults

The EN4216MR arrives with the tamper, low battery, and inactive trouble conditions
pre-programmed.

Default Trouble Condition Programming

7 System Status

System status information displays alarm and fault information on the LCD
display by default. Points in alarm are displayed as A

LARM

, with the point

number following. If more than one point is in alarm, the display scrolls
through each point. If a point has more than one alarm, the display scrolls
through each alarm. Fault conditions are indicated by F

AULT

in the LCD

display if there is no A

LARM

already displayed; point numbers are not

displayed. If no point is in alarm and there are no fault conditions, R

EADY

displays.

8 Point Status

P

OINT

S

TATUS

allows you to view detailed alarm and fault information. Point

status information is available without a password.

To access P

OINT

S

TATUS

:

1. From system status information, press the Enter button to access the

receiver’s three main menus. P

OINT

S

TATUS

displays.

2. Press Enter to display point status details.
3. Use the Up/Down buttons to scroll through the points; press Enter

again to view the outputs the displayed conditions are mapped to.

• Point status flags are defined as follows: A = Alarm (transmitter only);

T = Tamper; B = Low Battery; L = AC loss (repeater only); I = Inactive.

Note: If - - displays, the displayed condition has been mapped to a null
output.

9 Install & Service

Note: The default password is 3446.

The I

NSTALL

& S

ERVICE

menu is used to reset factory configuration, change

password, view signal strength, delete points, register transmitters, and
setup points for any of the programmed points.

To access the I

NSTALL

& S

ERVICE

menu:

1. From the system status information, press the Enter button to access

the receiver’s three main menu options.

2. Use the Up and Down buttons to navigate to the the I

NSTALL

& S

ERVICE

menu; press the Enter button.

3. Enter a password to access I

NSTALL

& S

ERVICE

menus.

9.1 Setup Point

1. From the I

NSTALL

& S

ERVICE

menu, press Enter at the S

ETUP

P

OINT

prompt.

2. Use the Up/Down buttons to scroll through point numbers; press the

Enter button to select a point.

• T

X

R

EGISTR

D

displays if a transmitter or repeater is currently

registered to this point; T

X

N

OT

R

EGSTR

D

displays if no transmitter is

registered to this point.

3. Press Enter to continue.
Supervision Time: Sets a time limit on missing transmitters.

• The valid range is 0 to 99 hours. The default is 60 minutes. Selecting

0 turns off supervision.

Caution: Turning off supervision can jeopardize the integrity of your
system. Inovonics does not recommend turning off supervision. For
supervision to function correctly, the supervision time must be set for an
interval greater than the transmitter check-in time.

a. Use the Up and Down buttons to adjust the supervision time; press
the Enter button to select.
b. Use the Up and Down buttons to toggle between Hrs (hours) and Min
(minutes); press the Enter button to select.

Select Security/Repeater: Configures point’s alarm and alert messages
as either a repeater or a security transmitter.

a. Use the Up and Down buttons to choose S

ELECT

S

ECURITY

for a

security transmitter or S

ELECT

R

EPEATER

for a repeater; press the Enter

button to select.

Vs

Jam

ou

tpu

t

Ground

T

a

mp

er out

pu

t

Reset

inp

u

t

Recei

ver

po

w

e

r loss

ou

tp

ut

Caution:
Incorrect
connections
may cause
damage to the
unit

NC
COM
NO

NC
COM
NO
NC
COM
NO

NC

COM

NO

NC

COM

NO

NC

COM

NO