14 ADT Focus 200 Plus / Focus Cadet Control Panel Wiring and Programming Information

14.1 Typical EN4216MR Receiver Connection to ADT Focus 200 Plus / Focus Cadet Control Panel

EN4216MR Function EN4216MR

Terminal

Panel Terminal

Keypad Text

Power in (12V DC)

Vs

(19) + Aux Power

n/a

Ground

GND

(20) - Aux Power

n/a

Alarm 1

NC (1)

(25) Point 1

(user text)

(Follower)

Com 1

(26) Common

NO (1)

Alarm 2

NC (2)

(27) Point 2

(user text)

(Follower)

Com 2

(28) Common

NO (2)

Repeater AC Loss

NC (3)

(29) Point 3

RF Repeater AC

(Follower)

Com 3

(30) Common

NO (3)

RF Pt Low Battery

NC (4)

(32) Point 4

RF Pt Low Batt

(Latching)

Com 4

(31) Common

NO (4)

RF Pt Tamper

NC (5)

RF Pt Trouble

(Latching)

Com 5

(34) Common

NO (5)*

(33) Point 5

RF Pt Inactive

NC (6)

(35) Point 6

RF Pt Inactive

(Follower)

Com 6

(34) Common

NO (6)

Power Loss

POWER LOSS

(36) Point 7

RF Recvr Power

(Follower)

(37) n/a

Receiver Tamper

TAMP *

n/a

n/a

RF Jam

JAM

(38) Point 8

RF System Jammed

(Follower)

(37) n/a

* Point 5 is normally open to allow RF Pt Tamper and Receiver Tamper on one loop.
The end-of-line resistor must not be in series with the wire from terminal NO (5) to terminal 33. Add the following 2 connections to
terminate the combined loop:

1.

Connect a wire from TAMP terminal to NO (5) terminal.

2.

Connect a 2K-ohm resistor from TAMP terminal to COM 5 terminal.