Inovonics EN4232MR User Manual

Page 10

Advertising
background image

© Inovonics, 2011 - www.inovonics.com

10

16 DMP XR500 Control Panel Wiring and Programming Information

16.1 Typical EN4232MR Receiver Connection to DMP XR500 Control Panel

EN4232MR Function

EN4232MR
Terminal

Panel Terminal

Keypad Text

Power in (12V DC)

Vs

(7) RED

n/a

Ground

GND

(10) BLK

n/a

NC (1)

Alarm 1

C (1)

(14) GND

Zone 1

(Follower)

NO (1)

(13) Z1

(user text)

NC (2)

Alarm 2

C (2)

(14) GND

Zone 2

(Follower)

NO (2)

(15) Z 2

(user text)

NC (3)

Repeater AC Loss

C (3)

(17) GND

Zone 3

(Follower)

NO (3)

(16) Z 3

RF Repeater AC

NC (4)

RF Pt Low Battery

C (4)

(17) GND

Zone 4

(Latching)

NO (4)

(18) Z 4

RF Pt Low Batt

NC (5)

RF Pt Tamper

C (5)

(20) GND

Zone 5

(Latching)

NO (5)

(19) Z 5

RF Pt Trouble

NC (6)

RF Pt Inactive

C (6)

(20) GND

Zone 6

(Follower)

NO (6)

(21) Z 6

RF Pt Inactive

Power Loss

POWER LOSS

(22) Z 7

Zone 7

(Follower)

GND

(23) GND

RF Recvr Power

Receiver Tamper

NO (TAMP) *

n/a

(Follower)

C (TAMP) *

n/a

RF Jam

NC (JAM)

(24) Z 8

Zone 8

(Follower)

C (JAM)

(23) n/a

RF System Jammed

* Receiver Tamper and Transmitter Tamper can be combined on one loop.

Connect a 2K-ohm resistor from TAMP NO (normall open) to TAMP C (common).

Wire from TAMP NO to 5 NO.

Wire from TAMP C to 5 C.

Advertising