Troubleshooting, E gl-r-im, If the gl-r is in an error condition – KEYENCE GL-R Series User Manual

Page 10: Current consumption, Weight

Advertising
background image

10

E GL-R-IM

Current consumption

*1 The above current consumption does not include the current consumed via OSSD output.
*2 If inputs other than EDM input turn on, consumption current per input increases by 2.5 mA.

Weight

Troubleshooting

If the GL-R is not functioning normally, check the GL-R indicators first.

The GL-R is in an error condition under the following situations.

The center indicators blink in red.

The 7-segment display indicates "".

If the GL-R does not demonstrate the above situations, the GL-R is not in an error condition.

If the GL-R is in an error condition

*1 All indicators on the transmitter may turn OFF.
*2 This error occurs only when the muting lamp error is configured to cause error condition by using the

configuration software.

Indication

Error name

Cause

Check and corrective action



Wiring error

The end cover on the
receiver is not connected.

Check that the end cover is installed on the receiver
correctly.

"Cable installation" (page 5)

The unit connection cable
is connected to the upper
part of the GL-R.

Connect the unit connection cable to the lower part of
the GL-R.

"Cable installation" (page 5)

Transmitter and receiver
are not the same model.

Check that all transmitter and receiver models are
paired correctly.

When the GL-R operates in wire synchronization system

The synchronization wire is
not wired correctly or
disconnected.

Check the wiring of the synchronization wire.

"Cable color and pin position" (page 6)

When the GL-R operates in one-line system

The unit connection cable
is connected to the
transmitter.

Connect the unit connection cable to the receiver.

Do not connect the unit connection cable to the
transmitter.

"Cable installation" (page 5)

The series connection
cable is connected to the
lower part of the GL-R.

Connect the series connection cable to the upper part
of the transmitter and receiver.

"Cable installation" (page 5)

When the GL-R is in series connection.

The sub unit is not
connected correctly.

Check for the direction of the sub unit installation.

Check whether the receiver of sub unit is connected
to the transmitter of main unit.

Check whether the total number of beam axes is
more than 240.

"Series connection" (page 4)

The sub unit is broken.

Check that the sub unit operates correctly when not in
series connection.

When the error is cleared by restarting the GL-R.

The synchronization wire is
affected by external noise.

Check for noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.

Units: mA

Units: mA

Units: mA

Model

Current

consumption (Max.)

Transmitter Receiver

GL-R23F

50

70

GL-R31F

54

71

GL-R39F

57

72

GL-R47F

60

74

GL-R55F

62

75

GL-R63F

64

77

GL-R71F

66

78

GL-R79F

67

80

GL-R87F

69

81

GL-R95F

71

83

GL-R103F

72

84

GL-R111F

74

85

GL-R119F

76

87

GL-R127F

78

89

Model

Current

consumption (Max.)

Transmitter Receiver

GL-R08H

43

66

GL-R12H

46

68

GL-R16H

50

69

GL-R20H

53

71

GL-R24H

57

72

GL-R28H

59

73

GL-R32H

61

74

GL-R36H

63

75

GL-R40H

65

76

GL-R44H

66

77

GL-R48H

68

79

GL-R52H

69

80

GL-R56H

71

81

GL-R60H

72

82

GL-R64H

73

83

GL-R72H

75

85

GL-R80H

77

87

GL-R88H

79

89

GL-R96H

81

91

Model

Current

consumption (Max.)

Transmitter Receiver

GL-R04L

37

66

GL-R06L

39

67

GL-R08L

41

68

GL-R10L

43

69

GL-R12L

46

70

GL-R14L

48

71

GL-R16L

50

72

GL-R18L

52

73

GL-R20L

54

75

GL-R22L

56

75

GL-R24L

57

76

GL-R26L

59

77

GL-R28L

60

78

GL-R30L

61

79

GL-R32L

62

80

Units: g

Units: g

Units: g

Model

Weight

Transmitter Receiver

GL-R23F

320

330

GL-R31F

430

440

GL-R39F

550

550

GL-R47F

660

670

GL-R55F

780

780

GL-R63F

890

900

GL-R71F

1000

1010

GL-R79F

1200

1200

GL-R87F

1300

1300

GL-R95F

1400

1400

GL-R103F

1500

1500

GL-R111F

1600

1600

GL-R119F

1700

1700

GL-R127F

1800

1900

Model

Weight

Transmitter Receiver

GL-R08H

210

210

GL-R12H

320

330

GL-R16H

430

440

GL-R20H

550

550

GL-R24H

660

660

GL-R28H

770

770

GL-R32H

880

890

GL-R36H

1000

1000

GL-R40H

1110

1110

GL-R44H

1220

1220

GL-R48H

1330

1340

GL-R52H

1440

1450

GL-R56H

1560

1560

GL-R60H

1670

1680

GL-R64H

1780

1790

GL-R72H

2010

2010

GL-R80H

2230

2240

GL-R88H

2450

2460

GL-R96H

2680

2690

Model

Weight

Transmitter Receiver

GL-R04L

210

210

GL-R06L

320

330

GL-R08L

430

440

GL-R10L

550

550

GL-R12L

660

660

GL-R14L

770

770

GL-R16L

880

890

GL-R18L

1000

1000

GL-R20L

1110

1110

GL-R22L

1220

1220

GL-R24L

1330

1340

GL-R26L

1440

1450

GL-R28L

1560

1560

GL-R30L

1670

1680

GL-R32L

1780

1790



Setting switch error

The configuration of the
setting switch is out of
specification.

Check the configuration of the setting switch.

"Setting switch" (page 3)

The setting switch is
configured to something
other than Channel 0 in
wire synchronization
system.



Configuration error

The configuration of the
setting switch overlaps the
configuration uploaded
from the configuration
software.

Modify the configuration of the setting switch or modify
the configuration by the configuration software.

"Setting switch" (page 3)

The unit configuration is
different from the
configuration uploaded
from the software.

Check the model name of main unit and sub unit and
whether the unit configuration from the software is
identical to the actual unit configuration.

The upload of configuration
has not been completed
correctly when using the
configuration software.

Upload the configuration again.



Interlock error

Interlock mode selection
input or reset input are
wired incorrectly.

Rewire the interlock mode selection input or reset input
correctly.

"Examples of Wiring" (page 6)



EDM error

EDM input is not
connected correctly.

If EDM function is needed, rewire the EDM correctly.

If EDM function is not needed, rewire the EDM and
AUX correctly or deactivate the EDM function by the
configuration software.

"Examples of Wiring" (page 6)

There is a welded contact
on the external device.

Replace the external device.



Receiver error

The receiver is affected by
ambient light.

Shield the receiver from ambient light.



Transmitter error

The transmitter is broken.

Replace the transmitter.

When the error is cleared by restarting the GL-R.

The transmitter is affected
by external noise.

Check for a noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.





OSSD1 error
OSSD2 error

When the error is cleared by restarting the GL-R.

OSSD is affected by
external noise.

Check for a noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.

There is a voltage surge
affecting the OSSD due to
an inductive load.

When the load is inductive such as relay, use a load
with a surge absorption device.

The power supply voltage
has fallen continuously or
experienced a sudden
drop.

Take measures by replacing the power supply,
increasing the power capacity, or dedicating the power
supply to the GL-R.

When the error is not cleared by restarting the GL-R.

OSSD is short-circuited
to 0 V or 24 V of power
supply.

OSSDs are short-
circuited to each other.

OSSD is short-circuited
to other wires.

Rewire the OSSD correctly.

"Examples of Wiring" (page 6)

Too much current is
flowing through the OSSD.

Check that the load does not consume more current
than the OSSD can handle.

"Specifications" (page 9)

OSSD is broken.

Replace the receiver.



Sub unit error

The sub unit is broken.

Replace the sub unit.

When the error is cleared by restarting the GL-R.

The sub unit or series
cable is affected by
external noise.

Check for a noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.



Communication error

*1

When the error is cleared by restarting the GL-R.

The synchronization wire is
not wired correctly or is
disconnected.

Check the connection of the synchronization wire.

The synchronization lines
in the cable are affected by
external noise.

Check for a noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.

The power supply voltage
has fallen continuously or
experienced a sudden
drop.

Take measures by replacing the power supply,
increasing the power capacity, or dedicating the power
supply to the GL-R.

When the error is not cleared by restarting the GL-R.

The synchronization wire is
not connected correctly or
is disconnected.

Check the connection of the synchronization wire.

The connection with the
GL-R in series is broken.

Replace the GL-R unit connected in series.

"Series connection" (page 4)



Muting lamp
disconnection error

*2

The muting lamp is not
connected correctly.

Check the connections.

The muting lamp is broken. Replace the muting lamp.



Muting lamp over
current error

*2

The muting lamp is not
connected correctly.

Check the connections.

Too much power is
consumed by the muting
lamp.

Make sure the muting lamp does not consume more
power than the GL-R can handle.

The muting lamp is broken. Replace the muting lamp.



Synchronization beam
axis error

When the GL-R operates in
optical synchronization
system, the fixed blanking
or muting function is
applied to both the upper
and lower beam axes (for
synchronization control).

Do not apply the fixed blanking or muting function to
at least the upper or lower axis.

Make the GL-R operate in one-line system or wire
synchronization system.

"Wiring system" (page 3)



:



System error

The power supply voltage
has fallen continuously or
experienced a sudden
drop.

Take measures by replacing the power supply,
increasing the power capacity, or dedicating the power
supply to the GL-R.

The GL-R is broken.

Replace the GL-R.

Indication

Error name

Cause

Check and corrective action

Advertising