English – KEYENCE SL-C Series User Manual

Page 46

Advertising
background image

Chapter 4 Checklist

4

English

ENGLISH

❏

If 2 or more sets of SL-C units are used - a series connection or light interference prevention
connection is used to prevent light interference.

See “3-6 Connection for Light Interference Preven-

tion” (

➮ page 3-5) and take measures to prevent light interference among each SL-C units.

3.

Check Using an Operation Test with the Machine Stopped

With the machine stopped, turn on the power of the SL-C and carry out the following tests using the
test piece included in the package. If you are using any of models SL-C**L having the detection
capability of 45 mm diameter, prepare a test piece having a diameter of 45 mm at customer's side, and
implement the test. If the floating blanking function is active, do not use the attached test piece, but
use a proper test piece that conforms to the description given in the SL-R12EX manual.

❏

The output status indicator (bar LED) on the SL-C turns red and stays red while the test piece is
present within the detection zone.

❏

When the power of the SL-C is turned on with no test piece in the detection zone, the output status
indicator as well as all eight bar LEDs turn green.

❏

The test piece can be detected regardless of its location as long as it is in the detection zone.

❏

If the SL-R11(E) restart interlock function is enabled, when the test piece is removed, confirm that
bar LEDs on the SL-C light up green, the output status indicator lights up red, and the SL-R11(E)
interlock indicator lights up yellow.

❏

When in the restart interlock state, the start/restart input causes the output status indicator to
change to green, and the SL-R11(E) interlock indicator to turn off.

❏

If the SL-R11(E) start interlock function is enabled, confirm that the bar LEDs light up green, the
output status indicator turns red, and the SL-R11(E) interlock indicator lights up yellow when the
power of the SL-C is turned on with no object in the detection zone.

❏

In addition, the output status indicator changes to green and the SL-R11(E) interlock indicator turns
off when there is a start/restart input while in the start interlock state.

Move the test piece for detection confirmation as illustrated in the figure below.

Star

t

Stop

4. Operation Test with the Machine Operating

This test confirms that the machine stops its operation.

❏

Place the test piece in the detection zone or protection zone of the SL-C. It is recommended to try
three locations: near the transmitter, near the receiver, and the central area of the detection zone.
The machine must stop by the detection of the test piece.

❏

The machine must remain stopped as long as the test piece is in the detection zone.

❏

The machine will not operate when the SL-C Series power supply has been interrupted.

❏

The overall response time of the machine, including the response time of the SL-C and the time it
takes for the machine to stop, must be shorter than the overall response time T used in the calcula-
tion of safety distances (

➮ See “2-2 Safety Distances” (page 2-5)).

4-2