2-3-5 Light Interference Prevention Method

This section explains how to install multiple units of the SL-CHS Series units without using the light
interference prevention cables prescrided in this instruction manual.

[Sensor installation location examples]

(1) Side by side

(2) Vertically stacked

(3) Parallel

(4) Separated by object

Tr

ansmitter

Receiv

er

Receiv

er

Tr

ansmitter

Tr

ansmitter

Receiv

er

Receiv

er

Tr

ansmitter

Receiv

er

Tr

ansmitter

Tr

ansmitter

Receiv

er

Receiv

er

Tr

ansmitter

Tr

ansmitter

Receiv

er

WARNING

To mount 2 or more sets of the of the SL-CHS Series without using the light
interference prevention cable specified in the instruction manual, install the SL-
CHS units as shown in the above diagrams, and then use the section 4

“Checklist”

(

➮ page 4-1) provided in the instruction manual to make sure the SL-CHS operates

properly. Not following this installation method could result in serious harm, such as
serious injury or death.