I.c.c. setting, 1 about maintenance, About maintenance – KEYENCE SJ-M200 User Manual

Page 11

Advertising
background image

10

3-4

Other Functions

Relationship between installation distance and wind speed according to air

flow rate

The relationship between wind speed and static elimination head installation distance varies according
to the air flow rate
Adjust the air supply flow rate referring to the following figures.

75

100 150 200 250 300 350

50

0

400mm

mm

50

25

0

-25

-50

-75

10m/s

2m/s

1m/s

75

200 300 400 500 600 700

100

0

1000mm

mm

50

25

0

-25

-50

-75

800 900

10m/s 5m/s

1m/s

2m/s

100

200 300 400 500 600 700

100

0

1500mm

mm

50

75

25

0

-25

-50

-75

-100

800 900 1000 1100 1200 1300 1400

10m/s

20m/s

5m/s

1m/s

1m/s

2m/s

2m/s

Air flow rate 250 Nl/min (pressure 0.5 MPa)

Air flow rate 20 Nl/min (pressure 0.01 MPa)

Air flow rate 60 Nl/min (pressure 0.08 MPa)

3-4

Other Functions

How to supply air

Supply air from the SJ-M010/020(G)'s Air Input Unit as
shown in the figure on the right.
Joints and tubes must be prepared separately.

Recommended joint

We recommend using a tube fitting (tube dia. 6mm, 8mm) made by PISCO for a joint to the Air Input
Unit.

Be sure to limit the tightening torque to 0.7 Nm. Tightening beyond this limit

may cause an accident or a malfunction.

Be sure to use the Air Input Unit. Using a different air supply may cause an

accident or a malfunction.

Rc1/8

Tube

Tube dia. 6 mm: PC6-01
Tube dia. 8 mm: PC8-01

CAUTION

3-4

Other Functions

I.C.C. Setting

The I.C.C. (Ion Current Control) can be turned on and off.
Turning off the I.C.C. allows the ion balance adjustment function to generate positive and negative ions
at a fixed ratio.

<Run mode>

<Select mode>

Either of them lit

Blink alternately

Hold down
for at least
1 second

Hold down for at
least 1 second
simultaneously

Change

Change

Change

Blink

Blink

Change the 4th LED from the top in the Select mode.

Press for a short time

: advances to the Setup mode

of the selected item

Hold down for at least 1 second : exits the Select mode and

returns to the Run mode

: moves the cursor up and

down

On the ion monitor, the currently selected items are lit in green and the
items whose default have been changed are lit in red.

I.C.C. is set at ON by default setting.

Items that satisfy both of these conditions blink in red and green
alternately.

Advance to the tube head setting from the Select mode in page 7, and
select either of the followings.
(1) Normal nozzle (green) (Default)
(2) Tube nozzle (red)

Select an appropriate nozzle according to the
head. Incorrect setting may cause accidents or
malfunction. When the tube nozzle is selected, the
ion level alarm will not be output correctly.

Important

4-1

About Maintenance

Maintenance must be performed periodically to ensure that the static elimination performance of the
SJ-M Series is fully demonstrated. Maintenance personnel should thoroughly read the descriptions
under "Safety Precautions" (

page 1), and perform maintenance paying attention to the following

points.

About Maintenance

The SJ-M Series uses high voltage. Before starting maintenance, be sure to

turn the power OFF. Failure to do so might result in electric shock or
malfunction.

Do not directly touch the electrode

probe. Take care not to touch these
probes even if the power is turned OFF.
Directly touching these probes may
cause personal injury.

When the SJ-M Series is used for a long period of time, the electrode probe becomes dirty due to the
adhesion of dust and dirt.
If the ion level alarm indicator lights, clean the electrode probe. If the electrode probe is used in a dirty
or dusty state, static elimination performance can no longer be fully demonstrated, resulting in
accidents or malfunction. We recommend periodically cleaning the electrode probe (as a guideline,
once every two weeks in a regular operating environment though this depends on the installation
conditions).
If cleaning the electrode probe does not improve the static elimination performance, or the ion level
alarm indicator frequently lights, replace the electrode probe.