Main specifications – KEYENCE XG-8700T User Manual

Page 8

Advertising
background image

8

Main Specifications

Model type

XG-8700T

Pixels

• With CA-HX500C/HX500M connected

5 mega-pixel mode: 2432(H) x 2040(V), approx. 4.96 mega-pixels
2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels

• With CA-HX200C/HX200M connected

2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels

• With CA-HX048C/HX048M connected

470 k pixel mode: 784(H) x 596(V), approx. 470,000 pixels
310 k pixel mode: 640(H) x 480(V), approx. 310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx. 240,000 pixels

• With XG-H500C/H500M connected

5 mega-pixel mode: 2432(H) x 2050(V), approx. 4.99 mega-pixels

• With XG-200C/S200C/H200C/200M/S200M/H200M connected

2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels
1 mega-pixel mode: 1024(H) x 960(V), approx. 980,000 pixels

• With XG-H100C/H100M connected 1000(H) x 1000(V), 1 mega-pixel
• With XG-035C/S035C/H035C/035M/S035M/H035M connected

310 k pixel mode: 640(H) x 480(V), approx. 310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx. 240,000 pixels

• With XR-HT40M connected: 2048 (H) x 2048 (V), approx. 4.19 mega-pixels
• With XR-HT15M connected: 1408 (H) x 1408 (V), approx. 1.98 mega-pixels
• With LJ-V connected:

512 (H) x 16384 (L), approx. 8.39 mega-pixels
1024 (H) x 8192 (L), approx. 8.39 mega-pixels
2048 (H) x 4096 (L), approx. 8.39 mega-pixels

Camera input

• With CA-EC80L/XG-EC80L equipped: 1 color/monochrome Area Scan Camera (Compatible with CA-HX500C/HX500M/HX200C/

HX200M/HX048C/HX048M)

• With CA-EC80HX equipped: 1 color/monochrome Area Scan Camera (Compatible with CA-HX500C/HX500M/HX200C/HX200M/

HX048C/HX048)

• With XG-EC80T equipped: 1 3D camera (Compatible with XR-HT40M/HT15M)
• With CA-EC80LJ/XG-EC80LJ equipped: 1 LJ-V (Compatible with LJ-V7000/7000P)
• With CA-EC80/XG-EC80 equipped: 2 color/monochrome Area Scan Cameras (Compatible with CA-HX500C/HX500M/HX200C/

HX200M/HX048C/HX048M and XG-H500C/200C/S200C/H200C/H100C/035C/S035C/H035C/H500M/200M/S200M/H200M/H100M/
035M/S035M/H035M, mixed connection possible)

Based on the connection of the expansion unit CA-E800/XG-E800, when the XG-EC80T is equipped, 1 3D Camera expansion unit
(maximum 2 cameras) can be connected, when the CA-EC80LJ/XG-EC80LJ is equipped, 1 LJ-V expansion unit (maximum 2 LJ-V) can be
connected, when the CA-EC80HX/CA-EC80L/XG-EC80L is equipped, 1 extra area scan camera (only the CA-HX500C/HX500M/HX200C/
HX200M/HX048C/HX048M; 2 cameras maximum) can be connected and when the CA-EC80/XG-EC80 is equipped up to 2 Area Scan
Camera expansion units (maximum 4 cameras) can be connected (Mixed connection possible). Mixed connection of XG-EC80T and
CA-EC8LJ/XG-EC80LJ is not supported.

Trigger input

Simultaneous capture by up to 4 cameras/individual capture can be selected. (when CA-EC80/XG-E800 is not connected, images from up
to two cameras can be captured at the same time)

Main image processor

DSP (High-speed)

Registered number of inspection settings

SD cards 1 and 2 can each hold 1000 programs (depending on the size of the SD card and the size of the programs), external switching
possible.

Number of registered screens

Maximum 1000 screens for each program (depending on SD card size), Image compression, image registration of position adjustment
images and partial image registration available. External switching possible based on variable reference.

SD card

• SD card slot x 2 (SDHC compatible)
• Compatible with OP-87133 (512MB), CA-SD1G (1GB: installed standard to SD1 slot), and CA-SD4G (4GB: SDHC)

Interface

Controlled input (compatible with
arbitrary assignment)

• 20 input (including four high speed inputs designed for trigger input)
• Input rating 26.4 V or lower, 2 mA or greater (3 mA or greater for high speed input terminal)

Controlled output (compatible with
arbitrary assignment)

• 28 output (including four high speed outputs designed for FLASH outputting linked to external device)
• NPN open collector

*1

Maximum 50 mA (30 V or less)

Encoder input

For the Open Collector Output (Dedicated to 24 V outputs) using the Control Input Terminal (2 systems)

Monitor output

Analog RGB Output, XGA (1024 x 768, 24 bit color)/SVGA (800 x 60, 24 bit color) Switch (can be set by the inspection settings unit)

Operation indicators

LED display for Power ON, Operation and ERROR

RS-232C

2 Port up to Maximum baud rate of 230400 bps
The digit output or control input/output and CA Series Touch Panel interface can be switched.

PLC link

• Numerical value output and control input/output using the RS-232C port or Ethernet port enabled (Do not use to connect to CC-Link,

EtherNet/IP and PROFINET.)

• Following PLCs are supported via link unit:

*2

KEYENCE: KV-700 Series, KV-1000 Series, KV-3000 Series, KV-5000 Series, KV-5500 Series, KV Nano Series
Mitsubishi Electric: MELSEC A Series (RS-232C only), Q Series, L Series
OMRON: SYSMAC C Series (RS-232C only), CP1/CS1/CJ1/CJ2 Series
YASKAWA Electric: MP900 Series (RS-232C only), MP2000 Series

Ethernet

• Numerical value output, and control input/output enabled.
• By the connection of KEYENCE PC application software, in addition to the function described above, uploading and downloading the

inspection settings, simulations, data, including image data can be sent or received.

• VisionDatabase function support (sold separately)
• For the FTP client function, the VNC server function (for clients other than for PC it will be only for the screen display), and BOOTP

function.

• 1000BASE-T/100BASE-TX/10BASE-T

USB

• By the connection of KEYENCE PC application software, in addition to numerical value output and control input/output, uploading and

downloading the inspection settings, simulations, data, including image data can be sent or received

• VisionDatabase function support (sold separately)
• USB2.0

CC-Link

• By connecting the optional CC-Link expansion unit CA-NCL10E, numerical value input/output and control input/output are enabled.

(Do not use to connect to PLC Link, EtherNet/IP and PROFINET.)

• Compatible to the Ver.1.10 remote device station, Ver.2.00 remote device station

EtherNet/IP

Numerical value input/output, and control input/output by using the Ethernet port enabled.
(Do not use to connect to PLC Link, CC-Link and PROFINET.)
• Compatible to the cyclic communication (max.1436 byte), and message communication
• Maximum number of connections 32
• Compatible with the conformance test Version.CT10.

PROFINET

Numerical value input, and control input/output by using the Ethernet port enabled.
• Compatible to the cyclic communication (max. 1408 byte)
• Compatible to the aperiodic (recorded data) communication
• Compatible with the Conformance Class A
• Do not use to connect to PLC Link, CC-Link and EtherNet/IP.

Console

• By the optional OP-84231, OP-84236 (without silk screen printing), various menu can be used
• Compatible to the operation assignment settings to the console button
• Compatible to the button activation and deactivation of each user group

Touch panel

• Setting operation from the CA Series touch panel used by the RS-232 port is possible
• For the dedicated touch menu or the operation button

Advertising