KEYENCE OP-87331 User Manual

Instruction manual, Ca-dz series thru-beam diffusion unit

Advertising
background image

96M11577

Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.

11577E 1021-1 96M11577 Printed in Japan

CA-DZ Series Thru-beam

Diffusion Unit

OP-87328/OP-87329/
OP-87330/OP-87331

Instruction Manual

Read this instruction manual before using the
product in order to achieve maximum
performance.
Keep this instruction manual in a safe place after
reading it so that it can be used at any time.

„

Symbols

This manual uses the following symbols so that you
can recognize important messages at a glance.
Please read it in its entirety.

The “OP-87328/OP-87329/OP-87330/OP-87331”
includes the following items. Check if the parts and
equipment listed below are included in the
package of the model you purchased.

F

Thru-beam Diffusion Unit
One unit of the following:
OP-87328 (50 mm use)/
OP-87329 (150 mm use)/
OP-87330 (300 mm use)/
OP-87331 (450 mm use)

F

Installation Screws M3 x L6
(OP-87328/OP-87329) x 4
(OP-87330) x 6
(OP-87331) x 8

F

Instruction Manual (this manual)

Install the thrubeam diffuser unit to the transmitter
of the CA-DZ that has had its diffuser panel
removed using all of the included installation
screws.

Introduction

It indicates a situation which, if
not avoided, could result in
product damage as well as
property damage.

Checking the Package Contents

NOTICE

How to install the CA-DZ Series

The Thru-beam Diffusion Unit is
only suitable for the specified
full length CA-DZ Series.
Do not install to a CA-DZ Series
of a different length or a device
other than the CA-DZ Series.

Appropriate tightening torque
0.5 Nm to 0.8 Nm