KEYENCE OP-87337 User Manual

Instruction manual, Macro lens mounting stand, Checking the package contents introduction

Advertising
background image

Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.

11649E 1031-1 96M11649

Printed in Japan

Macro Lens Mounting Stand

OP-87337

Instruction Manual

Read this manual before using the product in order to achieve maximum performance.

Keep this manual in a safe place after reading it so that it can be used at any time.

The OP-87337 is supplied with the following items. Check that all are included in the package.

F

Stand (Insulation installation plate attached) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

F

Metal Bracket for Lens Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

F

Plastic bracket for Lens end mounting (Holder, Bracket assembly complete) . . . . 1 set

F

Mounting screws (M4 x L16 mm 6-hole bolt double sems screw x 4) . . . . . . . . . . 1 set

F

Instruction Manual (this document)

* We make every effort to ensure products reach our customers without any damage.

However, if you encounter any defective, damaged, or missing parts, please contact

your nearest KEYENCE sales office.

This is the instruction manual for the Dedicated Mounting Stand for the Line Scan Camera

Macro Lens CA-LM0210/CA-LML0210. When using the CA-LM0210 or CA-LML0210, it is

necessary to fix the Lens Main Unit to the equipment using this item or a stand of similar

structure.

„

Symbols

This manual uses the following symbols so that you can recognize important messages at

a glance. Please read it in its entirety..

Refer to the diagram below to assemble the Stand and fix it to the Macro Lens.

1.

Temporarily fix the Plastic bracket for Lens end mounting to the Stand Main Unit,

after installing the Lens Mounting bracket for procedure 2, tighten using the

recommended torque.

2.

To tighten the bracket for fixing the Lens, tighten the round holes first, then

tighten the elliptical holes.

When attached to the CA-LM(L)0210, XG-HL02M/HL04M/HL08M

Stand weight: approximately 980g

Checking the Package Contents

Introduction

It indicates a situation which, if not avoided, could result in product

damage as well as property damage.

Installation

NOTICE

1

2

2

Recommended tightening torque:

1.0 to 1.3N m (Lens/ Stand Main Unit same)
Stand Main Unit Fixing recommended bolt:

M5 Hexagonal hole bolt double sems L-20 mm and

over x 4 (fix the Stand Main Unit by the lower portion.)

When installing the Stand Main Unit to the equipment, use the

included Insulation Installation Plate to ensure insulation from the

equipment. Since the Lens and the Camera have a Case Grounding, if

it is connected directly without insulation when there is a difference

in potential or where there is noise, it may cause damage to or

malfunction of the device.

Dimensions

NOTICE

58

37.6

68

79

94

62

141.1

(142.4)

34.75

(50)

LENS Center

Stand Main Unit screw positions

7.6

(30)

96M11649

Advertising