Connecting to the controller, Panel lock, Installation procedure – KEYENCE CA-MP120 User Manual

Page 2: Connecting the 24 vdc power source, Adjustment procedure, Specifications, Dimensions, Panel lock installation procedure

Advertising
background image

2

1. The PANEL LOCK will activate when the automatic adjustment indicator lights up.

2. The PANEL LOCK will be deactivated when the PANEL LOCK button is pressed.

1. Insert the CA-MP120 into the panel.

2. Using the 6 installation hooks on the top and bottom of the CA-MP120, tighten the screws

of the mounting bracket using a Phyllis-head screwdriver.

The CA-MP120 can not only be installed to the panel bracket, it can be installed to the
monitor stand for CA Series LCD monitor use (optional). For details inquire to your nearest
KEYENCE office.

If your monitor needs adjustment due to ambient light, the installation angle, or the
characteristics of the connected device, follow the procedure below.

1. Press the

button on the rear of the monitor. The setting menu is displayed.

2. Press the

button to move the cursor onto the item to change the setting.

3. Press the

button to change the setting of the item.

4. Press the

button to change the value/setting.

5. Press the

button to return to the status of step 1.

6. When you complete the adjustment, press the

button to exit the setting menu.

LCD monitor CA-MP120

Panel mounting diagram

Panel cut measurement

Connecting to the controller

Image signal
input

Connect by using an RGB monitor cable OP-66842 (3 m), an OP-87055
(10 m), or a commercially available analog RGB cable.

PANEL LOCK

Installation Procedure

• Tightening the mounting bracket with excessive force may deform

the casing. The proper tightening torque for achieving the drip-proof

feature is 0.3 Nm. However, note that a drip-proof effect may not be

obtained depending on the strength or shape of the panel.

• When installing the CA-MP120, make sure to leave a minimum

clearance of 20 mm around the product.

Connecting the 24 VDC Power Source

• Use electrical wiring AWG14 to AWG22.

• Make sure to connect the frame ground terminal for the 24 VDC

power source to a type D ground.

• The sizes of solderless connectors are shown below. Use connectors

that fit M3 screws.

• Tighten the screws with a torque of 0.5 to 0.75 Nm.

Adjustment Procedure

When no video signal is input, a blue screen (with message "NO SYNC
SIGNAL" for the first five minutes) is displayed instead of the setting menu.

Auto-escape function

If no button is pressed for about 10 seconds, the setting menu display is
turned off. When this occurs, the change(s) made so far will be saved.

Panel (Panel thickness): 1.0 to 4.0 mm

2

1

Mounting hook

Screw

Mounting bracket

Mounting bracket

Phillips screwdriver

NOTICE

NOTICE

5.8 mm or

smaller

Circular connector

5.8 mm or smaller

Y connector

Reference

MENU

MENU

MENU

EXIT

Reference

Item

Setting

BRIGHTNESS

Adjusts the brightness of the backlight of the LCD panel.

CONTRAST

Adjusts the contrast of the image.

COLOR MODE

Adjusts the color tone of RGB individually.

BLACK LEVEL

Adjusts the black level.

CLOCK

Adjusts the horizontal size of the screen by adjusting the
clock.

FOCUS

Reduces blurred characters and images by adjusting the
focus.

POSITION

Adjusts the horizontal/vertical position of the screen.

*1

AUTO
ADJUSTMENT

The input image signal is adjusted automatically to the most
appropriate setting.
Adjustment object: POSITION/CLOCK/FOCUS

POWER
SAVING

The screen is set when the screen automatically lights up or
when the PANEL LOCK is set. The PANEL LOCK is
deactivated by the

button.

BUTTON LOCK

All button operations are deactivated.
Also the

button operation is deactivated.

The lock is released when the

button is pressed for 3

seconds or more.

INFORMATION

Displays the device setting information, etc.

RECALL

Resets the settings to the factory default (initial) settings.

Specifications

Product name

LCD Monitor

Model

CA-MP120

Display element

a-Si, TFT active matrix method

Display color

16,777,216

No. of dots

1024 (W) x 768 (H) dots or 800 (W) x 600 (H) dots

Active display area

245 (W) x 184 (H) mm

Backlight

Approx. 100,000 hours (average)
(When installed in an upright position under 25°C (77°F))

Input signal

Analog RGB signal (0.7 Vp-p, 75

Ω), Horizontal/vertical

synchronization signal

Input signal mode

1024 (W) x 768 (H), Vertical frequency: 60 Hz or
800 (W) x 600 (H), Vertical frequency: 60 Hz

Input connector

High-density D-sub 15-pin female (3-way, inch screw)

Power-supply voltage

24 VDC ±10%

Current consumption

1.5 A max.

Ambient temperature

0 to +40°C (32 to 104°F)

Relative humidity

35 to 85%

Construction

Panel-mount type
Only the front face is dust-proof and splashproof equivalent to IP65

Weight

Approx. 2.3 kg

The TFT LCD panels may have bright dots that always illuminate and dark
dots that never illuminate. This is inevitable due to the manufacturing
process and is not a product failure.

Dimensions

PANEL LOCK

PANEL LOCK

MENU

Reference

(49.5)

6

186

(Active display area)

247.4

(Active display area)

360

15

6.5

255

55.5

28

342

240

35

75

75

4-M4
Depth: 10

(Unit: mm)

Mounting screw

Mounting bracket

157.5

242+1

0

344 +1

0

Panel thickness 1.6 to 4.0 mm

263

(Mounting bracket

external dimensions)

156.5

(Unit: mm)