PRACTICAL GUIDE TO INSTALLATION

Properly insulate the area around the fan to

minimize building heat loss and gain. (Fig.18)

Loose fill or batt insulation can be placed

directly over the fan housing in the attic.
Our fans and fan/light combination units do

not create excessive heat that is a common
problem with recessed light fixtures or some

competitor's fan/light combination. Our
efficient, cool-running motors and our LED

lighting unit do not create enough ambient
heat to be subjected to these limitations.

4 inches or 6 inches roof jack, waii cap,

or soffit vent with backdraft damper

Mechanicaliy connect duct to termination

and seal with mastic or approved foil

faced tape

2-3 ft straight run before elbow

In attic installation,

caulk box to drywall

Short piece of flexible duct helps
alignment and absorbs sound.

Clamps plus mastic or approved Foil tape tightly covers all metal

foil faced tape at all flex joints duct joints (glue PVC joints) Fig.18

Insulation

SPECIFICATIONS

Specifications

Model No.

Air

direction

Voltage

(V)

Frequency

(Hz)

Duct

diameter

(inches)

Noise

(sones)

Power consumption (W)

Speed

(rpm)

Air volume

atO.rWG

(CFM)

Weight

lb.(kg)

Fan

LED lighting unit

LIGHT

N.LIGHT

FV-08VKME3
FV-08VKSE3

Exhaust

120

60

4 or 6

<0.3

8

11.5

0.8

869

80

11.2(5.1)

HVI Certified performance based on HVI Procedures 915,916,and 920.

■ Reference specifications

Model No.

Air

direction

Voltage

(V)

Frequency

(Hz)

Duct

diameter

(inches)

Noise

(sones)

Power

consumption

(W)

Speed

(rpm)

Air volume

at 0.1 "WG

(CFM)

Weight

Ib.(kg)

FV-08VKME3
FV-08VKSE3

Exhaust

120

60

4 or 6

<0.3

6.5

828

70

11.2(5.1)

<0.3

5.6

798

60

<0.3

4.8

776

50

<0.3

4.2

765

40

<0.3

3.8

756

30

-

0.5 (*)

-

0

Reference performance based on HVI Procedures 915, 916, and 920. [(*) Standby wattage.]

PRODUCT SERVICE________________________________

Warning Concerning Removal of Covers.
The unit should be serviced by qualified technicians only.
Your product is designed and manufactured to ensure a minimum of maintenance.

Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7292 (USA)
or 1-800-669-5165 (Canada).

Panasonic Corporation of North America

One Panasonic Way, Secaucus, New Jersey 07094

www.panasonic.com

Panasonic Canada Inc.

5770 Ambler Drive, Mississauga, Ontario L4W 2T3

www.panasonic.ca

© Panasonic corporation 2012