INSTALLATION I (JOIST MOUNTING -1) CONTINUED

6. Refer to wiring diagram. (Wiring detail please refer

to the wiring diagram on page 6.)
Follow all the local electrical safety codes as well as

the National Electrical Code (NEC).

Using UL approved wire nuts, connect house power

wires to ventilating fan wires. (Fig.4-1, Fig.4-2)

A

caution

O

Mount junction box cover carefully so that

lead wires are not pinched.

7. Finish ceiling work. Ceiling hole should be aligned

with the inside edge of the flange. (Fig.5)

IMPORTANT:

Remove the tapes from louver and springs
before installation. As shown below:

'Tapes«

FV-08VKME3

FV-08VKSE3

8. Insert the grille mounting spring on the wiring side

into the slot and insert the plug connector i into

the housing of the lighting unit. (Fig.6)

A

caution

O

O

Before turn on the light, make sure the

connector at the correct position. If not, the

lighting can't work.

The claw of connector must latch the rib
completely. (Fig.6)

9. Insert the sensor unit into slot of the grille.

Fix the sensor lead wire into the clasp

(1 position).(FV-08VKME3)(Fig.7)

Conduit^^V;

Junction box /

Ferrite Core
(For reducing the

electromagnetic noise)

Earth ground

to green

Wire nut

Neutral to white

Neutral to white

Live to blaci
(LIGhfT)

Live to black

(Ventilating fan)

FV-08VKME3

Fig.4-1

Conduit-

Junction box

Ferrite Core

(For reducing the
electromagnetic noise)

Earth ground

to green

Wire nut

Live to black

(Ventilating fan)

Neutral to white

Two red wires_

Live to black

(Connect to

(LIGHT)

manual wall switch)

FV-08VKSE3

Fig.4-2

Ceiling

Unit: inches (mm)

Tr

.1

After finishing the ceiling job, fill gap between flange
and ceiling with caulk or other sealant to prevent air

leakage.

5

Plug connector I

Mounting spring

Grille

LED Lighting unit

Lighting unit

Y

''insert

plug connector I

Fig.6