PROGRAMMING
INSTRUCTIONS FOR AUTOMATIC DISPENSE
1. Turn Power Switch ON (toggle switch inside door).
2. PRESS and HOLD [red] STOP Button with one hand.
3. PRESS and HOLD [green] DISPENSE Button with other hand.
4. RELEASE [red] STOP Button ONLY.
5. Continue to HOLD [green] DISPENSE Button for 5 SECONDS, then RELEASE.
6. PRESS and RELEASE [green] DISPENSE Button. Product begins dispensing.
When it reaches the "DESIRED VOLUME",
7. PRESS and RELEASE [green] DISPENSE Button to SET "DESIRED VOLUME".
DISPENSE Button can be "jogged" to top off.
8. PRESS and RELEASE [red] STOP button to LOCK IN "DESIRED VOLUME".
Repeat steps 1 to 8 for each Dispense Button.

PROGRAMMING INSTRUCTIONS FOR MANUAL DISPENSE
1. PRESS AND HOLD STOP [red] BUTTON WITH ONE HAND.
2. PRESS AND HOLD DISPENSE [green] BUTTON WITH OTHER HAND.
3. RELEASE STOP [red] BUTTON.
4. RELEASE DISPENSE [green] BUTTON.
5. PRESS AND RELEASE STOP [red] BUTTON.

The Total Time The Water Is Running Is Accumulated And Saved Into Memory. For Normal Operation,
Press and Release Dispense Button.

The Automatic Dispense Buttons are factory programmed to dispense 8 oz. of Water per cup.

PRODUCT STRENGTH ADJUSTMENTS:

The JAVA units have variable speed control auger motors [CD151 with variable
speed of 10 to 130 RPM].
Drink or Product Strength can be changed by adjusting the Gram Throw Dial on inside door panel.
The Gram Throw is factory preset at approx. 2.4 (2.2 gr. per 8 oz. cup) for the JAVA2-LP machines.
The water flow rate adjustment for the dispense valve should remain fixed bet. 1 - 1.3.

HOT WATER FLOW RATE ADJUSTMENTS:


Note: Remove right side panel to access the Water Dispense Valves, .

TO ADJUST HOT WATER FLOW RATE:
1. Remove right side panel to access the Water Dispense Valves, mounted on tank.
2. Locate adjustment screw on Dispense Valve.
3. Using Allen Key or flat screwdriver rotate, 1/4 turn at a time,
CLOCKWISE to decrease water flow, or COUNTERCLOCKWISE to increase water flow.
4. Check water flow output, after each 1/4 turn.



3