Maintenance (cleaning), Installation m (joist mounting - ii) – Panasonic FV-08VK3 User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

INSTALLATION m (JOIST MOUNTING - II)

Joist situation:

Spacing B is

10

1/2

inches (266 mm) to

111/2 inches (292 mm)

on joists

1. If the spacing B is 10 1/2 inches (266 mm) to 11 1/2

inches (292 mm) on joists, please follow the
installation step as below.

2. Secure 4 long screws (ST 4.2X20) at flange of frame. (Fig.12)

3. Follow steps 4 to 10 of installation I (page

8

and page 9)

to complete the installation work.

MAINTENANCE (CLEANING)

WARNINS:

Disconnect power source before working on unit. Routine
maintenance must be done every year.

CAUTION:

1. Never use gasoline, benzene, thinner or any other

such chemicals for cleaning the ventilating fan.

2. Do not immerse motor in water when cleaning.
3. Do not soak resin parts in water over 140°F (60°C).

1. Remove grille pull down one mounting spring(no sensor

lead passed). Remove sensor unit then pull down the

other mounting spring. (Squeeze mounting spring and

pull down carefully). (Fig.13, Fig.14)

2. Clean grille. (Don't put into hot water. Use non-abrasive

kitchen detergent, wipe dry with clean cloth) (Fig. 15)

3. The grille should be dry after cleaning.

4. Remove dust and dirt from fan body using a vacuum

cleaner. (Fig. 16)

5. Using a cloth dampened with kitchen detergent, remove

any dirt from fan body. Wipe dry with clean cloth. (Fig. 17)

6

. Replace grille.

1 1

PDF created with pdfFactory Pro trial version www. pdffactory. com

Ceiling

Fig.16

Advertising