SWITCH INDICATION

FV-13VKM3

FV-13VKS3

FV-08VKM3
FV-08VKS3

Low speed air volume

preset switch

Switch indications

Switch indications

on blower unit

on blower unit

Low speed air-volume preset switch positions

High/Low delay time

preset switch

FV-13VKM3
FV-13VKS3

Air volume

[CFM]

0

50

70

90

110

FV-08VKM3
FV-08VKS3

0

30

40

50

60

70

Factory setting : FV-13VKM3/FV-13VKS3: 70CFM; FV-08VKM3/FV-08VKS3: 50CFM.
Position "0" : Fan stop.
Position : use for factory test only.

High/Low delay time preset switch positions

Delay Time

[min]

0.5

1

2

3

5

10

20

30

60

Factory setting : 20 minutes.

Position

: use for factory test only.

(Models of FV-13VK3 and FV-08VK3 and FV-05VK3 have only one steady air volume.)

OPERATION________________________________

■ Sensor detectible range (For models of FV-13VKM3 and FV-08VKM3 only)

The distance that motion

can be detected is limited

to 10 feet (3m).
The field of view of the

sensor is 90".

(Room temperature is

25”C)

Motion

>

The low speed is determined by air volume preset switch.

>

The delay time is determined by High/Low delay time preset switch.

>The unit maintains the higher speed for an adjustable duration of 0.5 to 60 minutes, after motion

is no longer detected.

mm

IS
>>

moo

il

Human

active

a

I/Ì

Z

$0 il^

Fan active

At low

speed

when motion is

detected, fan runs
at the high speed.

Remains running

at high speed until
the delay time has

passed.

mm

il

Human

active

![fe

Fan active

At low
speed

When manual wall

switch Is closed,
fan runs at the high
speed.

When manual wall

switch is opened.
Fan remains running
at high speed until

the delay time has

passed.

(Models of FV-13VK3 and FV-08VK3 and FV-05VK3 have only one steady air volume, when the power switch

is closed, FV-13VK3 works steadily at 130CFM and FV-08VK3 works steadily at 80CFM and FV-05VK3

works at 50 CFM, when the power switch is opened, it will stop running.)