NOTE 1: Shipping weight does not include motor and drive.

NOTE 2: Operating weight includes estimated weight for motor and drive for Arrangements “A” and “D”.
Also includes maximum sludge capacity based on 100 lb. per cubic foot for Arrangement D hopper in the
event of plugged drain line.

Table 2. Shipping and Operating Weight in Pounds

RotoClone

Arrangement A

Arrangement D

Size

Shipping Weight (lbs.)

Operating Weight (lbs.)

Shipping Weight (lbs.)

Operating weight (lbs.)

8

225

425

1,725

2,625

10

360

610

1,810

3,010

12

630

880

2,030

3,380

14

990

1,340

2,790

5,320

16

1,260

1,710

3,760

6,310

20

1,620

2,270

5,420

9,650

24

1,890

2,590

7,190

13,290

27

2,970

3,720

--

--

30

3,870

5,020

--

--

33

4,860

6,360

--

--

36

5,850

7,350

--

--

45

13,500

16,000

--

--

6.0 Weights & Water Usage Tables

Table 1. Normal Water Supply Rates - Type W RotoClones

Size

Arrangement A

Arrangement D

GPM Supplied

GPM Supplied

40 psi

50 psi

60 psi

40 psi

50 psi

60 psi

8

1.1

1.2

1.3

2.1

2.2

2.5

10

1.5

1.6

1.8

3.1

3.4

3.8

12

1.8

2.0

2.2

4.8

5.4

5.9

14

2.3

2.5

2.9

5.3

5.9

6.5

16

3.5

3.9

4.3

7.5

8.4

9.2

20

4.5

5.0

5.5

8.5

9.5

10.4

24

5.5-6.0

6.2-6.7

6.8-7.3

13.5-14.0

15.1-15.6

16.6-17.1

27

7.0-7.5

7.9-8.4

8.7-9.2

----

----

----

30

8.0

8.9

9.8

----

----

----

33

12.0

13.4

14.7

----

----

----

36

14.0-15.0

14.7-15.7

16.7-17.1

----

----

----

45

21.0-22.0

23.6-24.6

25.9-26.9

----

----

----

NOTE 1: Decreased or increased water requirements can be provided by changing nozzle size.

NOTE 2: For air temperatures in excess of 300° F cooling spray nozzles should be provided in inlet duct to compensate for evaporation.

A safe approximation will be 0.2 GPM of additional water per 1000 CFM for each 100° F temperature reduction.