AAF International Type N RotoClone User Manual

Page 13

Advertising
background image

13

(MAXIMUM

) OPERAT

ING LINE

#5

(MINIMUM)

OPERATI

NG LINE

#1

OPERATING

LINE #2

OPERATING

LINE #4

OPERATIN

G LINE #

3

12

11

10

9

8

7

6

5

600 700 800 900 1000 1100 1200

Figure 8. Typical chart of Type N RotoClone pressure loss for exhaust
volume variations and given operating lines. The Type N RotoClone
must operate on one of the operating lines. RotoClone size
multiplied by cfm./ft. impeller gives rating in cfm.

Flow Rate—cfm/ft. Impeller

Total Collector—Pressure Drop " w

.g.

Type N RotoClone Performance Curves

If further help is required there is an American Air Filter Representative available to check the operation of your RotoClone and
answer any questions concerning erection, operation, or maintenance.

Operating Line

1

2

3

4

5

Maximum Pressure Drop in. w.g.

7.5

9.0

10.6

11.2

11.7

Advertising