To configure SIP-Tie Trunks, follow these steps:
1.
Open the MultiVoIP configuration tool.
2.
Select Configuration > Voice/Fax and configure these parameters:
•
Set Select Channel to Channel 3
•
Set DTMF to Out of Band – Fixed Duration
•
Set Out Of Band Mode to SIP Info
•
Set Coder to Manual
•
Set Selected Coder to [email protected]
•
Set Auto Call/OffHook Alert to Auto Call
•
Check Generate Local Dial Tone.
•
Set Phone Number to 150 (This means when the gateway sends a call to MaxCS, it will try to
ring extension 150. If extension 150 does not exist, the call will be sent to the MaxCS Auto
Attendant system.)
3.
Select Configuration > Interface and configure the following parameters:
•
Set Select Channel to Channel 3
•
Set Interface Type to FXO