Page 15 American Access Systems / Security Brands, Inc.

Should you make an entry error, simply press the * key and reenter the correct data, or press the # and start over.
An easy way to check if the APB feature is enabled or not is to press (MASTER CODE) +308 and check if the red LED is
on or off. If it’s on, the submode is enabled. Then press the # key to exit.

To disable Anti-passback press:

(MASTER CODE) + 308 + (MASTER CODE)
APB MASTER CODE DESCRIPTION: The APB master code is used to erase the APB status of a certain code in the
system. In some instances it may become necessary to perform this operation if a mistake was made by an end
user and the APB status needs to be reset. When this code is entered, the APB status of a code will be erased from
memory. This code is not accessible while in the sleep mode (see submode 103).

To clear APB status of a specific code:

(APB MASTER CODE) + (SPECIFIC ACCESS CODE)

Example: To clear the status of code 1234 press:

(APB MASTER CODE) + 1234

“309”

SubMode 309 (QUIET MODE)

NOTE: From the factory, QUIET MODE is enabled.
DESCRIPTION: If you want to hear the good or bad beeps at your desk when an access code is entered at the slave
keypad you can disable the quiet mode. This sub-mode can be toggled on or off by pressing:

(MASTER CODE) + 309(*) + (MASTER CODE)

(*) 1 BEEP AND RED LED ON = FEATURE ENABLED

(*) 2 BEEP AND RED LED OFF = FEATURE DISABLED

“400”

SubMode 400 (PRINT AUDIT TRAIL)

NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO INVOKE THIS SUBMODE.
DESCRIPTION: The PROX 2000 II is capable of storing up to 1000 transactions in it’s history buffer. Once the unit
reaches 1000 transactions the unit will roll over and overwrite the first transaction unless the buffer is cleared (see
submode 499).

To print out the history buffer enter the 4 digit “MASTER CODE” followed by submode “400”.

(MASTER CODE) + 400
The unit will continually print out all transactions from first transaction to last. Should you make an entry error, simply
press the * key and reenter the correct data. Once the unit has finished it will respond with a GOODBEEP and exit
from the program mode. To halt printing simply turn the printer off.

“401”

SubMode 401 (PRINT OUT ALL CURRENT ACCESS CARDS)

NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO USE THIS SUBMODE.
DESCRIPTION: This sub-mode is used to print out all access cards in the system.

To print out all access cards enter the 4 digit “MASTER CODE” followed by submode “401”.

(MASTER CODE) + 401

“402”

SubMode 402 (PRINT AUDIT TRAIL ON SPECIFIC CARD)

NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO INVOKE THIS SUBMODE.
DESCRIPTION: This sub-mode is used to print out the audit trail (history) of a specific card. The unit goes through the
1000 code history buffer and finds when the specific card has been used and prints the times and dates.

To print out the history of a specific card enter the 4 digit “MASTER CODE” followed by submode “402” followed by the

“SPECIFIC CARD”.

(MASTER CODE) + 402 + (SPECIFIC CODE)

Example: To print out the history of code:

1315 enter

“MASTER CODE” + 402 + 1315

Advertising