STEP 2-SYSTEM CONNECTIONS HOOKUP STEPS

(A). Make all your prox slave connections BEFORE you apply power to the master unit. To connect power to your
new desk unit plug the wall tranformer into an outlet and insert the other end in the back of the unit.
(B). Connect the device(s) to be controlled to the appropriate terminal(s).
(C). Double check your connections. When you are sure you have the unit hooked up correctly, apply power to the
unit. If this is the first time power up, the unit will perform some self diagnostics and setup the memory. The unit will
flash the LED’s several times while it is performing the first time setup. If everything goes O.K., you will hear a GOOD
BEEP from the unit. If the unit does not perform as above, quickly turn off power to the unit and contact American
Access Systems.

NOTE: THE UNIT WILL ONLY PERFORM THE SELF DIAGNOSTICS AND MEMORY SETUP THE FIRST TIME IT IS POWERED UP.

FROM THERE ON OUT THE UNIT WILL SOUND A GOOD BEEP IMMEDIATELY AFTER POWER IS APPLIED.

USING A SLAVE WITH THE PROX 2000 II
The prox 2000 II communicates with two 23-006 slave proximity readers utilizing wiegand technology.
Please see instruction manual included with the 23-006.

NOTE: Do not run your gate control wires in the same shielded cable as your slave communication wires.

CONNECTION FOR 12 VOLT BULB

RESET

BUTTON

MASTER BOARD

CONNECTOR FOR

COMMUNICATIONS

AND RELAYS BOARD

PRINTER

POWER

TRANSFORMER PLUG

-IN

COMMUNICATIONS AND RELAYS BOARD

SEE PAGE 6 WIEGAND

COLOR CODES FOR

SLAVE INTERFACE