Technical specification – BASO E Series AGA User Manual

Page 6

Advertising
background image

6 E Series EC/AGA Approved Intermittent Pilot Ignition Control Installation Instructions

Technical Specification

Product

EC/AGA Universal Intermittent Pilot Ignition Control

Ignition Type

Indirect

Ignition Source

High voltage spark, capacitive discharge

High Voltage Cable
Maximum Length

1,220 mm (48 in.) (Resistive wire recommended, rated for at least 15Kv.)

Flame Sense Cable
Maximum Length

1,220 mm (48 in.)

Flame Detection Means

Flame Rectification

Flame Detection Type

Local or Remote

Minimum Flame Current

0.15 microamperes

Flame Failure Response
Time

2 seconds maximum

Maximum Spark Gap

5.1 mm (0.2 in.)

Power Requirements

Control:
Operation Current:

24 VAC (+/- 20%), 50/60 Hz
0.2 A nominal + valves

Contact Rating

Main Valve:
Pilot Valve:
Alarm Output

2 A maximum
2 A maximum
1 A maximum

Wiring Connections

6.35 mm (1/4 in.) male spade

Burner Rating

117 kW (400,000 Btu/hr)

Ambient Operating and
Storage Temperature

-40 to 77

°C (-40 to 176°F)

Humidity

95% RH noncondensing

Type of Gas

Natural, Liquefied Petroleum (LP), Manufactured, Mixed or LP Gas-Air Mixture

Packaging

Bulk pack supplied to original equipment manufacturer (individual pack [-1AAC] or overpack

Bulk Pack Quantity

25

Pack Weight

Bulk pack (-1AAD) 6.36 kg (14 lb)
Individual pack (-1AAC) .454 kg (1 lb.)

Agency Listing

EC Certification Number EC-86/10/147

AGA Certification Number 7811

Specifications Standards

ANSI Standard Z21.20
CAN/CSA-C22.2 No. 199

The performance specifications are nominal and conform to acceptable industry standards. All agency
certification of BASO products is performed under dry and controlled indoor environmental conditions. Use of
BASO products beyond these conditions is not recommended and may void the warranty. If the product is
exposed to water (dripping, spraying, rain, etc.) or other harsh environments, it must be protected. The original
equipment manufacturer or end user is responsible for the correct application of BASO products. For questionable
applications, please consult BASO Gas Products LLC. BASO Gas Products LLC shall not be liable for damages
or product malfunctions resulting from misapplication or misuse of its products

1007 South 12

th

Street

PO Box 170
Watertown, WI 53094

www.baso.com

1-877-227-6527 (1-877-BASOGAS

Published in U.S.A.

Advertising
This manual is related to the following products: