5050_4_5.pdf, Programming – Braeburn 5050 User Manual

Page 3

Advertising
background image

4

5

cont.

PROGRAMMING

4

4.2

Setting Current Time of Day and Day of Week

NOTE:

It is important for you to set the current time of day (note AM/PM indicator in

display), and the current day of week correctly to avoid problems with program execution.

PROGRAMMING

4

4.1

Default Thermostat Settings

Function

Status After Reset

Operation Mode

Normal Operating Mode

Temperature Hold

Extended and Temporary Hold Cleared

Clock

12:00 pm, Monday

Room Temperature

70˚ F (21.0˚ C), to be renewed within

5 seconds

Setpoint Temperature

According to system switch:

62˚ F (17.0˚ C) for Heat or Off

83˚ F (28.0˚ C) for Cool

Temperature Scale

˚F or ˚C dependent on switch setting

Operating Program

DAY program, Monday

Low Battery Warning

Off, to be renewed within 5 seconds

Temperature Differential

0.5˚ F (0.25˚ C)

Residual Cooling Fan Delay

60 seconds

Short Cycle Protection Timer Reset

Output Relays

Off

Extended Hold

Indefinite

Keypad Lock

Unlocked

Adaptive Recovery Mode

Reset

Filter Check Monitor

0 Days OFF

Recirculating Fan Timer

Reset with 120 minute off cycle

NOTE:

The thermostat will return to normal operating mode automatically after 15

seconds if no key is pressed. It will also return to normal operating mode immediately if

the RETURN button is pressed.

1. When in normal operating mode, press the DAY/TIME

keypad button. The LCD display will be cleared

except for the time, am/pm indicator and the day of

the week. The hour portion of the time will flash.
2. Press the or button to set the current hour.
3. Press DAY/TIME button again, the minute portion of

the time will flash.
4. Press the or button to set the current minute.
5. Press DAY/TIME button again, the day of the week indicator will flash.
6. Press the or button to set the current day of the week.
7. Press DAY/TIME button again and the thermostat will return to normal operating mode.

4.3

Setting Thermostat User Options

The default setting is 0.5˚ F (0.25˚ C). The room temperature must change 0.5˚ F (0.25˚ C) from

the setpoint temperature before the thermostat will initiate the system in heating or cooling.

NOTE:

Once you have finished setting the temperature differential you can wait 15

seconds and the thermostat will automatically return to the normal operation mode.

Otherwise, you can press RETURN button again to set the Residual Cooling Fan Delay.

Setting the Temperature Differential

Setting Residual Cooling Fan Delay

The default setting is 60 seconds. During the

COOL mode of operation, the fan will stay on for

60 seconds after the setpoint has been satisfied, and the compressor has turned off.

3. After pressing the RETURN button again, the display

will show "

FAN XX," where "XX" is the fan delay

time in seconds.

Setting the Extended Hold Time (see also section 5.3)

The default setting is Long (indefinite) Hold. If the HOLD feature is activated, the current setpoint

will be held until HOLD is released.
6. After pressing the RETURN button again, the display

will show "

HOLD LG", where LG is indefinite hold.

HOLD

Setting the Filter Check Monitor (see also section 5.4)

10. Press the or button to change the Filter Monitor

interval to the desired value of 0 (disabled), 30, 60,

90, 120, or 180 days.
11. Press the RETURN button again to set the Recirculating Fan cycle, or wait 15 seconds for
the thermostat to return to the normal mode.

FILT

The default user options are compatible with most systems and applications. They are

normally set at the time of installation and usually do not require any modification under

normal operating conditions. If you wish to change these settings, simply follow the

instructions below.

NOTE:

The temperature differential settings are the same for both the heating and

cooling systems.

1. In normal operating mode, press and hold the

RETURN button for 4 seconds. The LCD display

will show "

d1 X", where "X" equals the ˚F / ˚C

differential setting. This is the current temperature

differential setting.
2. Press the or button to set the temperature

differential to your desired setting of 0.5˚, 1˚, or 2˚ F

(0.25˚, 0.5˚, or 1˚ C).

4. Press the or button to change the Residual

Cooling Fan Delay to the desired setting of 0 (disabled),

30, 60, or 90 seconds.
5. Press the RETURN button again to set the Extended

Hold Time or wait 15 seconds to return to the normal mode.

7. Press the or button to change the Extended

Hold time from indefinite (

LG) to 24 hours (SH).

8. Press the RETURN button again to set the Filter Check

Monitor or wait 15 seconds for the

thermostat to

return to the normal mode.

The default setting is 0 days (Filter Monitor disabled).
9. After pressing the RETURN button again, the display

will show "

FILT XXX SET", where XXX is the Filter

Monitor interval (number of days since last warning).