Configuration
Use the following instructions to configure the Premier 3-Zone Controller.
1. Open J1 jumper for dual transformer installations.
2. Open J2 short cycle protection jumper for system test.
Note: Replace J2 when system testing is completed or leave J2 open if compressor has built in
short cycle protection.
3.
Press
▲ and then press ▲ to raise or ▼ to lower the Hi Temp cutout.
4.
Press
▼ and then press ▲ to raise or ▼ to lower the Low Temp cutout.
5. Press
▲ and ▼ at the same time to adjust purge time. Press ▲ to raise or ▼
to lower the
purge time.
Figure 4
6
▲
▲
RH
RC
Y1
Y2
G
G2
W1
AUX
W2
O/B
C
HI/LOW LIMIT
CUTOUT ADJUST
J2-SHORT CYCLE
PROTECTION
EQUIPMENT
Braeburn
3-Zone
JI REMOVE TO SEPARATE
RH AND RC TERMINAL
SUPPLY TEMP
HI TEMP
LO
TEMP
PURGE
DELAY
J2 jumper
J1 jumper
HI/LOW
temp cutout
adjustment