220700 p2.pdf, Instructions for wiring humidifier, Figure 5a – Braeburn 220750 User Manual

Page 2: Figure 5b, Figure 5d, Figure 5e

Advertising
background image

5

FIGURE 5A

ACC

EAC

HOT

FURNACE

OR FAN

CONTROL

120 VAC

FURNACE

CONTROL

FIELD SUPPLIED

RECEPT & SWITCH

C

HUMIDIFIER

RED

POWER TO HUMIDISTAT

YELLOW

CONTROL

NOTE: Red wires are for humidistat power if required.

DO NOT CONNECT RED WIRES TO ANOTHER POWER

SOURCE OR ONE ANOTHER. DOING SO WILL VOID WARRANTY.

CAP OFF -

DO NOT CONNECT

TOGETHER

HUMIDISTAT

FIGURE 5B

HOT

MANUAL HUMIDISTAT

120 VAC WITH CURRENT

SENSING RELAY

FIELD SUPPLIED

RECEPT & SWITCH

C

HUMIDIFIER

RED

POWER TO HUMIDISTAT

YELLOW

NOTE: Red wires are for humidistat power if required.

DO NOT CONNECT RED WIRES TO ANOTHER POWER

SOURCE OR ONE ANOTHER. DOING SO WILL VOID WARRANTY.
NOTE: Yellow wires are for Humidistat Control. DO NOT APPLY

VOLTAGE TO YELLOW WIRES. DOING SO WILL VOID WARRANTY.

CURRENT

SENSING

RELAY

SINGLE OR

MULTI-SPEED FAN

C

HI

LO

CAP OFF -

DO NOT CONNECT

TOGETHER

HUMIDISTAT

INSTRUCTIONS FOR WIRING HUMIDIFIER

On furnaces with output terminals ACC, or

EAC check output voltage to determine

that terminals are 115V. Connect on-off

switch in series with the hot wire.

On furnaces where it is desirable to use a

current sensing relay, the humidifier may

be wired from a continuous 115 volt

power source. Install the on/off switch in

series with the hot or black wire. Install

the Braeburn

®

229050 Current Sensing

Relay in series with the humidistat circuit.

The Current Sensing Relay will detect

furnace operation and supply power to

the humidifier accordingly.

FIGURE 5C

ACC

EAC

HOT

DIGITAL HUMIDISTAT

120 VAC WITH CONTROL FROM

FURNACE BOARD

FURNACE

OR FAN

CONTROL

120 VAC

FURNACE

CONTROL

FIELD SUPPLIED

RECEPT & SWITCH

C

HUMIDIFIER

RED

POWER TO HUMIDISTAT

YELLOW

CONTROL

ACN

ACL

HUM

HUM

TO OUTDOOR

SENSOR

HUMIDISTAT

NOTE: Red wires are for humidistat power.

DO NOT CONNECT RED WIRES TO ANOTHER POWER

SOURCE OR ONE ANOTHER. DOING SO WILL VOID WARRANTY.

FIGURE 5D

HOT

DIGITAL HUMIDISTAT

120 VAC WITH CURRENT

SENSING RELAY

FIELD SUPPLIED

RECEPT & SWITCH

C

HUMIDIFIER

RED

POWER TO HUMIDISTAT

YELLOW

ACN

ACL

HUM

HUM

HUMIDISTAT

NOTE: Red wires are for humidistat power.

DO NOT CONNECT RED WIRES TO ANOTHER POWER

SOURCE OR ONE ANOTHER. DOING SO WILL VOID WARRANTY.
NOTE: Yellow wires are for Humidistat Control. DO NOT APPLY

VOLTAGE TO YELLOW WIRES. DOING SO WILL VOID WARRANTY.

CURRENT

SENSING

RELAY

SINGLE OR

MULTI-SPEED FAN

C

HI

LO

FIGURE 5E

BRAEBURN

®

HUMIDITY

CONTROL THERMOSTAT

RED

YELLOW

C

BRAEBURN

HUMIDITY CONTROL

THERMOSTAT

NOTE: Red wires must be capped off. DO NOT

CONNECT TOGETHER. DOING SO WILL VOID WARRANTY.

ISOLATION

RELAY

RED

CAP OFF -

DO NOT CONNECT

TOGETHER

YELLOW

HOT

FIELD SUPPLIED

RECEPT & SWITCH

C

HUMIDIFIER

H

On systems where it is desirable to control

humidity levels in the conditioned space, a

Braeburn humidity controlling thermostat

may be used. Install a 24 VAC 1 Amp

minimum isolation relay as shown in

Figure 5E.

NOTE: Yellow wires are for Humidistat Control. DO NOT APPLY

VOLTAGE TO YELLOW WIRES. DOING SO WILL VOID WARRANTY.

NOTE: ALL WIRING SHOULD COMPLY WITH LOCAL ELECTRICAL CODES.

NOTE: Yellow wires are for Humidistat Control. DO NOT APPLY

VOLTAGE TO YELLOW WIRES. DOING SO WILL VOID WARRANTY.

MANUAL HUMIDISTAT

120 VAC WITH CONTROL

FROM FURNACE BOARD

On furnaces with output terminals ACC, or

EAC check output voltage to determine

that terminals are 115V. Connect on-off

switch in series with the hot wire.

On furnaces where it is desirable to use a

current sensing relay, the humidifier may

be wired from a continuous 115 volt

power source. Install the on/off switch in

series with the hot or black wire. Install

the Braeburn 229050 Current Sensing

Relay in series with the humidistat circuit.

The Current Sensing Relay will detect

furnace operation and supply power to

the humidifier accordingly.

NOTE:Yellow wires are for Humidistat Control. DO NOT APPLY

VOLTAGE TO YELLOW WIRES. DOING SO WILL VOID WARRANTY.