Turn on water supply and plug in power cord to check operation of

humidifier. Set humidistat to a demand setting. With the furnace off, the

solenoid valve should be closed and the humidifier fan not running. Start

the furnace, the solenoid valve should open and the humidifier fan run

when the blower or burner circuit is energized. Check flow of water through

distributor trough and evaporator pad. The standard yellow orifice will

supply approximately 3.5 GPH of water at a line water pressure of 60 psi.

Leave humidistat set at the recommended setting.

Replace evaporator pad assembly and humidifier cover. Insert low

voltage six connector wiring harness from cover into chassis solenoid

harness.

6

8

CIRCUIT DESCRIPTION

The humidifier is connected to the 120 volt AC circuit through a control

relay. The secondary coil of an isolation transformer, a diode and resistor

supply 24 volts for the control circuit which also includes the humidistat and

relay coil. When the control circuit is completed by the humidistat, the relay

closes, supplying 120 volts to the fan motor and 24 volts to the

solenoid valve.