Operation, Connecting electrical loads – Champion Power Equipment 76533 User Manual

Page 18

Advertising
background image

15

ENGLISH

76533

OPERATION

Connecting Electrical Loads

1. Let the engine stabilize and warm up for a few

minutes after starting

2. Plug in and turn on the desired 120 Volt AC single

phase, 60 Hz electrical loads.

– DO NOT connect 3-phase loads to the generator.

– DO NOT connect 50 Hz loads to the generator.

– DO NOT overload the generator.

Connecting a generator to your electric utility company’s power
lines or to another power source may be against the law. In
addition this action, if done incorrectly, could damage your
generator and appliances and could cause serious injury or even
death to you or a utility worker who may be working on nearby
power lines. If you plan to run a portable electric generator
during an outage, please notify your electric utility company
immediately and remember to plug your appliances directly into
the generator. Do not plug the generator into any electric outlet
in your home. Doing so could create a connection to the utility
company power lines. You are responsible for ensuring that your
generator’s electricity does not feed back into the electric utility
power lines.
If the generator will be connected to a building electrical system,
consult your local utility company or a qualified electrician.
Connections must isolate generator power from utility power and
must comply with all applicable laws and codes.

NOTE

If the engine starts but does not run make certain that
the generator is on a flat, level surface. The engine
is equipped with a low oil sensor that will prevent the
engine from running when the oil level falls below a
critical threshold.

NOTE

When the battery switch is in the “ON” position, the
switch will light up if the battery is sending out a
charge. If the switch does not light up while in the “ON”
position, check that the battery connection is still good.

NOTE

The supplied 12V 7AH battery does re-charge while the
engine is running, but it is also recommended that the
battery be fully charged at least once per month.

NOTE

LPG Cont’d.

If the ignition switch is held down in the “Start” position
longer than 5 seconds it could damage the starter.

CAUTION

NOTE

Observing frost on LPG containers and regulators

is common during operation and normally is not an

indication of a problem. As LPG vaporizes and travels

from the tank to the generator engine it expands. The

amount of frost that forms can be affected by the size of

the container, the amount of fuel being used, the humidity

of the air and other operating conditions. In unusual

situations this frost may eventually restrict the flow of LPG

gas to the generator resulting in deteriorating performance.

For example, if the tank temperature is reduced to a

very low level then the rate at which the LPG vaporizes

is also reduced and may not provide sufficient fuel flow

to the engine. This is not an indication of a problem with

the generator but only a problem with the flow of gas

from the LPG container. If generator performance seems

to be deteriorating at the same time that ice formation

is observed on tank valve, hose or regulator then some

actions may be taken to eliminate this symptom.

In these rare situations it can be helpful to reduce or

eliminate the cold fuel system effects by doing one of the

following:

– Exchanging fuel tanks to allow the first tank to warm

up, repeating as necessary

– Placing the LPG container at the end of the generator

near the handle, where engine fan air flows out from

the generator. This air is slightly heated by flowing over

the engine. The container should not be placed in the

path of the muffler outlet.

– The container can be temporarily warmed by pouring

warm water over the top of the tank.

6. Push the ignition switch to the “ON” position.

7. Push the battery switch to the “ON” position.

8. ELECTRIC START: Press and hold the ignition switch

to the “START” position. Release as the engine begins

to start. If the engine fails to start within five seconds,

release the switch and wait at least ten seconds before

attempting to start the engine again.

9. RECOIL START: Pull the starter cord slowly until

resistance is felt and then pull rapidly.

10. Do not over-choke. As soon as engine starts, gradually

move the choke lever to the “RUN” position over a 2-5

second duration.

LPG

1. Make certain the generator is on a flat, level surface.

2. Disconnect all electrical loads from the generator.

Never start or stop the generator with electrical

devices plugged in or turned on.

3. Fully open the LPG cylinder fuel knob.

4. Turn the LPG fuel valve to the “ON” position.

5. Move the choke lever to the “75% Choke” detent turn

position. (A)

a. For restarting a warm engine, move the choke

lever to the “75% CHOKE” detent position.

A

Advertising