Do Not Overload Generator

Capacity

Follow these simple steps to calculate the running and starting
watts necessary for your purposes.
1. Select the electrical devices you plan on running at the

same time.

2. Total the running watts of these items. This is the amount

of power you need to keep your items running.

3. Identify the highest starting wattage of all devices

identified in step 1. Add this number to the number
calculated in step 2. Surge wattage is the extra burst of
power needed to start some electric driven equipment.
Following the steps listed under “Power Management” will
guarantee that only one device will be starting at a time.

Power Management

Use the following formula to convert voltage and amperage to
watts:

Volts x Amps = Watts

To prolong the life of your generator and attached devices,
follow these steps to add electrical load:
1. Start the generator with no electrical load attached
2. Allow the engine to run for several minutes to stabilize.
3. Plug in and turn on the first item. It is best to attach the

item with the largest load first.

4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.

Never exceed the specified capacity when adding
loads to the generator.

NOTE

Operation using the alternative main jet at
elevations lower than the recommended minimum
altitude can damage the engine. For operation at
lower elevations, the standard main jet must be
used. Operating the engine with the wrong engine
configuration at a given altitude may increase
its emissions and decrease fuel efficiency and
performance.

WARNING

Stopping the Engine Cont’d.

Operation at High Altitude

The density of air at high altitude is lower than at sea

level. Engine power is reduced as the air mass and air-

fuel ratio decrease. Engine power and generator output

will be reduced approximately 3½% for every 1000

feet of elevation above sea level. This is a natural trend

and cannot be changed by adjusting the engine. At high

altitudes increased exhaust emissions can also result

due to the increased enrichment of the air fuel ratio.

Other high altitude issues can include hard starting,

increased fuel consumption and spark plug fouling.

To alleviate high altitude issues other than the natural

power loss, Champion Power Equipment can provide a

high altitude carburetor main jet. The alternative main

jet and installation instructions can be obtained by

contacting Customer Support. Installation instructions

are also available in the Technical Bulletin area of the

Champion Power Equipment internet site.

The part number and recommended minimum altitude

for the application of the high altitude carburetor main

jet is listed in the table below.

In order to select the correct high altitude main jet

it is necessary to identify the carburetor model. For

this purpose, a code is stamped on the side of the

carburetor. Select the correct main jet part number

corresponding to the carburetor code found on your

particular carburetor.

Stopping the Engine

1. Turn off and unplug all electrical loads. Never start

or stop the generator with electrical devices plugged
in or turned on.

2. Let the generator run at no-load for several minutes

to stabilize internal temperatures of the engine and
generator.

3. Turn the gasoline fuel valve to the “OFF” position if

operating by gasoline.

4. Turn the LPG cylinder knob to the “CLOSE” or “OFF”

position if operating by LPG.

5. Let the engine run until fuel starvation has stopped

the engine. This usually takes a few minutes.

6. Press the ignition switch to the “OFF” position.
7. Turn battery switch to the “Off” Position.

Important: Always ensure that the Fuel Valve and the
Ignition Switch are in the “OFF” position when the
engine is not in use.

When turning off the generator after LPG operation, make
sure the LPG cylinder knob is in the fully closed position.

NOTE

If the engine will not be used for a period of two (2) weeks
or longer, please see the Storage section for proper engine
and fuel storage.

NOTE

Carburetor

Code

Main Jet

Part Number

Altitude

P22-4-H

Standard

27.131017.01.H

3500 Feet
(1067 Meters)

Altitude

27.131017.01.01.H

P22-4-Z

Standard

27.131017.01.Z

Altitude

27.131017.01.01.Z

Advertising