Troubleshooting

Before you call for service ...

If you are having an operating problem, check

the chart to see what the cause might be before
you call for assistance.

PROBLEM

CHECK IF

WHAT TO DO

Unit won’t run.

• Power cord is plugged into a live

circuit with proper voltage.

• Fuse has blown or circuit breaker has

tripped. Also, check if a time-delay
fuse has been used.

• System Control is set to OFF.

• Local power has failed.

• Firmly plug power cord into

electrical outlet. Check circuit
voltage at fuse/circuit breaker box.

• Replace fuse with a time-delay

fuse of the correct capacity. Reset
circuit breaker.

• Set System Control to another

setting.

• Wait for power to be restored.

Unit blows fuses
or trips circuit
breaker.

• Time-delay fuse being used is of

correct capacity.

• An extension cord is being used.

• Cooling circuit was turned off and on

again quickly.

• Replace fuse with a time-delay

fuse of the correct capacity.

• Do not use an extension cord

with this or any other appliance.

• Wait at least 3 minutes after

turning cooling circuit off before
trying to restart unit.

Unit turns on and

off, or does not
cool room.

• Filter is dirty.
• Inside evaporator coils and

outside condenser coils are dirty.

• There is excessive heat or moisture

in room.

• Fan speed is too low.

• Thermostat setting is too low.

• Clean filter. (See page 5.)
• Clean coils. (See page 6.)

• Use exhaust fans to reduce

room heat, or set Exhaust
Control to CLOSED to reduce
moisture.

• Set System Control to a higher

setting.

• Set Thermostat Control to a

higher number.

Normal operating sounds...

When your room air conditioner is operating

normally,

you will hear sounds such as:

• Droplets of water hitting the condenser, causing

a “pinging" or “clicking" sound. Water droplets
help to cool the condenser.

• Air movement from the fan, especially on HI

COOL setting.

• “Clicks" from the cooling cycle.

Sounds also may be caused by house construc­
tion - such as vibration of the unit due to wall
construction or unsteady window mounting area.

Advertising